W DOC AIRBUS | AMM A320F

Installation of the Temperature Sensor


TASK 30-73-17-400-003-A
Installation of the Temperature Sensor


ZONE: 131
FIN: 10DW ** ON A/C NOT FOR ALL
FIN: 300DW ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
131
FORWARD CARGO COMPARTMENT
825
FOR [10DW] (SENSOR,TEMPERATURE-)
131HW
FOR [300DW] (SENSOR,TEMPERATURE-)
131PW, 131RW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 30-73-00-720-001-A
Functional Test of the Potable Water Ice-Protection
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 30-73-17-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
Subtask 30-73-17-010-055-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
   (2) Make sure that the FWD cargo-compartment door 825 is open.
   (3) Make sure that the CARGO COMPT LIGHT switch 6LU is at ON.
   (4) In the FWD cargo-compartment, make sure that these panel(s) is (are) removed:
     (a) FOR [10DW] (SENSOR,TEMPERATURE-)
131HW
     (b) FOR [300DW] (SENSOR,TEMPERATURE-)
131RW 131PW
Subtask 30-73-17-865-057-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUPOT WIP-HEATER-LINE1DWA02
2000VUPOT WIP-HEATER-CTL2DWA01
4. Procedure
Subtask 30-73-17-420-053-A ** ON A/C NOT FOR ALL
A. Installation of the Sensor
   (1) On the potable water pipe, install the clamp sensor assembly (1) and the clamp (2) with the screws (3) and (4).
   (2) Tighten the screws (3) and (4).
   (3) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (4) Make sure that all the electrical connections are clean and in the correct condition.
   (5) Connect the two wires of the sensor to the terminal block.
   (6) Install the sleeve (5) around the clamp sensor assembly (1).
   (7) Make sure that the sleeve (5) is correctly installed around the sensor and the pipes.
   (8) Install the velcro tape (6) to attach the sleeve (5) around the clamp sensor assembly (1).
Subtask 30-73-17-865-058-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUPOT WIP-HEATER-LINE1DWA02
2000VUPOT WIP-HEATER-CTL2DWA01
Subtask 30-73-17-720-052-A ** ON A/C NOT FOR ALL
C. Do the functional test of the potable water ice-protection (Ref. AMM TASK 30-73-00-720-001).
5. Close-up
Subtask 30-73-17-410-052-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the panel(s):
     (a) FOR [10DW] (SENSOR,TEMPERATURE-)
131HW
     (b) FOR [300DW] (SENSOR,TEMPERATURE-)
131RW 131PW
   (3) Set the CARGO COMPT LIGHT switch 6LU to OFF.
   (4) Close the FWD cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
   (5) Remove the access platform(s).
Subtask 30-73-17-862-052-A ** ON A/C NOT FOR ALL
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).