W DOC AIRBUS | AMM A320F

Test of the External Power-Supply Contactor of the Yellow Electric Pump


TASK 29-24-55-700-002-A
Test of the External Power-Supply Contactor of the Yellow Electric Pump


FIN: 3805GX
FIN: 3806GX
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 29-24-55-860-052-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-42-00-861-001).
   (2) Safety precautions
CAUTION: MAKE SURE THAT YOU OBEY THE SAFETY CONDITIONS FOR OPENING OF THE FWD CARGO DOOR.
     (a) Before you open the FWD cargo door, make sure that the
   (3) On the circuit breaker panel 2000VU, put the MAIN BUS switch to the ON position.
Subtask 29-24-55-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUHYDRAULIC/SOL VALVES/G/Y/B/LEAK/TST1881GPN35
121VUHYDRAULIC/SOL VALVES/G/Y/PTU1801GLN34
121VUHYDRAULIC/LGCIU/SYS22GAQ35
122VUDOORS/CARGO1MJT12
122VUELEC/EXT PWR/LT CLT/NOT IN/USE6XGX30
123VUY HYD/ELEC/PUMP3802GXAB06
Subtask 29-24-55-865-054-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
122VUELEC/AC PWR/SVCE/CTL3XXV29
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
Subtask 29-24-55-010-053-A
D. Get Access
   (1) Unlock the handle of the FWD cargo compartment door.
4. Procedure
Subtask 29-24-55-710-051-A
A. Do this test:
ACTION
RESULT
1.On the control panel of the FWD cargo compartment:
  • Turn the selector to the OPEN position and hold it.
In the Yellow hydraulic bay:
  • The Yellow electronic pump starts.

    On the cargo door area:
  • The cargo door starts to open.
2.On the C/B panel 121VU:
  • Close the C/B 3XX.
In the Yellow hydraulic bay:
  • The Yellow electric pump stops.

    On the cargo door area:
  • The cargo door movement stops.
NOTE: The closing of the C/B 3XX energizes the relay 7XX and thus stops the power supply from the contactor 3806GG.
3.On the C/B panel 121VU:
  • Open the C/B 3XX.
In the Yellow hydraulic bay:
  • The Yellow electric pump starts to operate again.

    On the cargo door area:
  • The cargo door re-starts to move.
4.On the control panel of the FWD cargo compartment:
  • Release the selector and turn it to the CLOSE position and hold it until the cargo door is closed.
On the cargo door area:
  • The cargo door is closed
  • The Yellow electric pump stops.
5. Close-up
Subtask 29-24-55-865-055-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
122VUELEC/AC PWR/SVCE/CTL3XXV29
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
Subtask 29-24-55-942-054-A
B. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Make sure that the FWD cargo compartment door is correctly closed and locked (Ref. AMM TASK 52-30-00-860-002).
   (3) De-energize the aircraft electrical network (Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 08:13:32 UTC