Test of the External Power-Supply Contactor of the Yellow Electric Pump
TASK 29-24-55-700-002-A
Test of the External Power-Supply Contactor of the Yellow Electric Pump
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 29-24-55-860-052-A
Subtask 29-24-55-710-051-A
Subtask 29-24-55-865-055-A
[Rev.10 from 2021]
2026.04.01 00:27:11 UTC
Test of the External Power-Supply Contactor of the Yellow Electric Pump
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 29-24-55-860-052-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-42-00-861-001).
(2) Safety precautions
Subtask 29-24-55-865-053-A (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-42-00-861-001).
(2) Safety precautions
CAUTION:
MAKE SURE THAT YOU OBEY THE SAFETY CONDITIONS FOR OPENING OF THE FWD CARGO DOOR.
(a) Before you open the FWD cargo door, make sure that the - Safety conditions
- Aircraft configurations
- Access to FWD cargo door (Ref. AMM TASK 52-30-00-860-001) are correct.
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 29-24-55-865-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/SOL VALVES/G/Y/B/LEAK/TST | 1881GP | N35 |
| 121VU | HYDRAULIC/SOL VALVES/G/Y/PTU | 1801GL | N34 |
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 122VU | DOORS/CARGO | 1MJ | T12 |
| 122VU | ELEC/EXT PWR/LT CLT/NOT IN/USE | 6XG | X30 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-24-55-010-053-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| ** ON A/C ALL | |||
| 122VU | ELEC/AC PWR/SVCE/CTL | 3XX | V29 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
D. Get Access
(1) Unlock the handle of the FWD cargo compartment door.
4. Procedure(1) Unlock the handle of the FWD cargo compartment door.
Subtask 29-24-55-710-051-A
A. Do this test:
5. Close-up| ACTION | RESULT |
|---|---|
1.On the control panel of the FWD cargo compartment:
| In the Yellow hydraulic bay:
|
2.On the C/B panel 121VU:
| In the Yellow hydraulic bay:
NOTE: The closing of the C/B 3XX energizes the relay 7XX and thus stops the power supply from the contactor 3806GG. |
3.On the C/B panel 121VU:
| In the Yellow hydraulic bay:
|
4.On the control panel of the FWD cargo compartment:
| On the cargo door area:
|
Subtask 29-24-55-865-055-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 29-24-55-942-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| ** ON A/C ALL | |||
| 122VU | ELEC/AC PWR/SVCE/CTL | 3XX | V29 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
B. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Make sure that the FWD cargo compartment door is correctly closed and locked (Ref. AMM TASK 52-30-00-860-002).
(3) De-energize the aircraft electrical network (Ref. AMM TASK 24-42-00-862-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Make sure that the FWD cargo compartment door is correctly closed and locked (Ref. AMM TASK 52-30-00-860-002).