Removal of the Hydraulic Low-Pressure Switch Tube
TASK 29-13-49-000-005-A
Removal of the Hydraulic Low-Pressure Switch Tube
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-13-49-860-077-A ** ON A/C NOT FOR ALL
Subtask 29-13-49-020-066-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 08:07:40 UTC
Removal of the Hydraulic Low-Pressure Switch Tube
WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING:
DO NOT TOUCH THE HYDRAULIC SYSTEM COMPONENTS FOR A SHORT TIME AFTER THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
CAUTION:
DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CONTAINER 5 L (1.32 USGAL) |
| No specific | 3 | COVER - PROTECTION |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| No specific | 1 | WRENCH - STANDARD |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM2] (ENGINE-2) | |
| 447AL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-10-00-864-002-A | Depressurize the Yellow Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
Subtask 29-13-49-860-077-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the Yellow hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-10-00-864-002)
(2) Depressurize the Yellow hydraulic reservoir (Ref. AMM TASK 29-14-00-614-001).
(3) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Yellow hydraulic system:
Subtask 29-13-49-941-071-A ** ON A/C NOT FOR ALL (1) Make sure that the Yellow hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-10-00-864-002)
(2) Depressurize the Yellow hydraulic reservoir (Ref. AMM TASK 29-14-00-614-001).
(3) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Yellow hydraulic system:
- on the ground service panel 198CB.
B. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(3) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Yellow hydraulic system:
(6) Put a CONTAINER 5 L (1.32 USGAL) below the hydraulic low-pressure switch tube (15) to collect the remaining fluid.
Subtask 29-13-49-010-067-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
- put WARNING NOTICE(S) to tell persons not to start the engine.
(3) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Yellow hydraulic system:
- in the cockpit, on the HYD section of the overhead panel 40VU.
- make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(6) Put a CONTAINER 5 L (1.32 USGAL) below the hydraulic low-pressure switch tube (15) to collect the remaining fluid.
C. Get Access
(1) Open the left fan-cowl door (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM2] (ENGINE-2)
open the door 447AL.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the engine.
Subtask 29-13-49-865-059-A ** ON A/C NOT FOR ALL (1) Open the left fan-cowl door (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM2] (ENGINE-2)
open the door 447AL.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the engine.
D. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/Y HYD/PUMP ENG2/MONG | 3700GD | Q37 |
Subtask 29-13-49-020-066-A ** ON A/C NOT FOR ALL
A. Removal of the Hydraulic Low-Pressure Switch Tube
PRE SB RA32029-13
(1) Disconnect the low-pressure switch tube (15) from the pressure hose/tube and let the fluid flow in the CONTAINER 5 L (1.32 USGAL).
(4) Remove the low-pressure switch tube (15) from the engine.
(5) Put COVER - PROTECTION on the low-pressure switch tube (15), the fitting on the pressure hose/tube and the hydraulic low-pressure switch.
END OF PRE SB RA32029-13
Subtask 29-13-49-020-117-A ** ON A/C NOT FOR ALL PRE SB RA32029-13
(1) Disconnect the low-pressure switch tube (15) from the pressure hose/tube and let the fluid flow in the CONTAINER 5 L (1.32 USGAL).
NOTE: Use a second WRENCH - STANDARD to hold the fitting on the pressure hose/tube when you loosen the coupling nut on the tube.
(2) Disconnect the low-pressure switch tube (15) from the hydraulic low-pressure switch. NOTE: Use a second WRENCH - STANDARD to hold the pressure switch when you loosen the coupling nut on the tube.
(3) Remove the bolts (5) and the washers (10) that attach the clamps (20) to the channel. Remove the clamps (20) from the low-pressure switch tube (15). (4) Remove the low-pressure switch tube (15) from the engine.
(5) Put COVER - PROTECTION on the low-pressure switch tube (15), the fitting on the pressure hose/tube and the hydraulic low-pressure switch.
END OF PRE SB RA32029-13
B. Removal of the Hydraulic Low Switch Tube
POST SB RA32029-13
(1) Disconnect the low-pressure switch hose/tube assembly (17) from the pressure hose/tube and let the fluid flow into the CONTAINER 5 L (1.32 USGAL).
(4) Remove the bolts (7), the washers (10) and the nuts (25) that attach the clamps (20) to the channel. Remove the clamps (20) from the low-pressure switch hose/tube assembly (17).
(5) Remove the low-pressure switch hose/tube assembly (17).
(6) Put COVER - PROTECTION on the low-pressure switch hose/tube assembly (17), the fitting on the pressure hose/tube and the hydraulic low-pressure switch.
END OF POST SB RA32029-13
Subtask 29-13-49-020-118-A ** ON A/C NOT FOR ALL POST SB RA32029-13
(1) Disconnect the low-pressure switch hose/tube assembly (17) from the pressure hose/tube and let the fluid flow into the CONTAINER 5 L (1.32 USGAL).
NOTE: Use a second WRENCH - STANDARD to hold the fitting on the pressure hose/tube when you loosen the coupling nut on the tube.
(2) Disconnect the low-pressure switch hose/tube assembly (17) from the hydraulic low-pressure switch. NOTE: Use a second WRENCH - STANDARD to hold the pressure switch when you loosen the coupling nut on the tube.
(3) Remove the bolt (7) and the washer (10) that attach the clamp (20) to the channel. Remove the clamp (20) from the low-pressure switch hose/tube assembly (17). (4) Remove the bolts (7), the washers (10) and the nuts (25) that attach the clamps (20) to the channel. Remove the clamps (20) from the low-pressure switch hose/tube assembly (17).
(5) Remove the low-pressure switch hose/tube assembly (17).
(6) Put COVER - PROTECTION on the low-pressure switch hose/tube assembly (17), the fitting on the pressure hose/tube and the hydraulic low-pressure switch.
END OF POST SB RA32029-13
C. Removal of the Hydraulic Low Switch Tube
POST SB RA32029-15
POST SB RA32029-16
(1) Disconnect the low-pressure switch hose assembly (19) from the pressure hose/tube and let the fluid flow into the CONTAINER 5 L (1.32 USGAL).
(4) Put COVER - PROTECTION on the low-pressure switch hose assembly (19), the fitting on the pressure hose/tube and the hydraulic low-pressure switch.
END OF POST SB RA32029-15
END OF POST SB RA32029-16
POST SB RA32029-15
POST SB RA32029-16
(1) Disconnect the low-pressure switch hose assembly (19) from the pressure hose/tube and let the fluid flow into the CONTAINER 5 L (1.32 USGAL).
NOTE: Use a second WRENCH - STANDARD to hold the fitting on the pressure hose/tube when you loosen the coupling nut on the tube.
(2) Disconnect the low-pressure switch hose assembly (19) from the hydraulic low-pressure switch. NOTE: Use a second WRENCH - STANDARD to hold the pressure switch when you loosen the coupling nut on the tube.
(3) Remove the low-pressure switch hose assembly (19). (4) Put COVER - PROTECTION on the low-pressure switch hose assembly (19), the fitting on the pressure hose/tube and the hydraulic low-pressure switch.
END OF POST SB RA32029-15
END OF POST SB RA32029-16
Hydraulic Low-Pressure Switch Tube