W DOC AIRBUS | AMM A320F

Reactivation of the Spoiler Elevator Computer 3 (SEC)


TASK 27-94-00-440-802-A
Reactivation of the Spoiler Elevator Computer 3 (SEC)


ZONE: 210
FIN: 1CE3
1. Reason for the Job
MMEL 27-94-03P
SEC 3 (FAA ONLY)
MMEL 27-94-01
SPOILER ELEVATOR COMPUTER (SEC) 3 (FAA ONLY)
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 27-94-00-861-056-A
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 27-94-00-865-058-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUFLIGHT CONTROLS/SEC3/SPLY21CE3Q19
4. Procedure
Subtask 27-94-00-440-051-A
A. Reactivation of the Spoiler Elevator Computer 3 (SEC)
   (1) On the circuit breaker panel 121VU:
     (a) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
21CE3.
   (2) On the overhead panel, on the FLT CTL panel 24VU:
     (a) Remove the WARNING NOTICE(S).
     (b) Push the SEC 3 pushbutton switch.
5. Close-up
Subtask 27-94-00-860-060-A
A. Put the aircraft back to its initial configuration.
   (1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
   (2) Make sure that the work area is clean and clear of tools and other items.