Deactivation of the Spoiler Elevator Computer 3 (SEC)
TASK 27-94-00-040-802-A
Deactivation of the Spoiler Elevator Computer 3 (SEC)
1. Reason for the Job
MMEL 27-94-03P
SEC 3 (FAA ONLY)
MMEL 27-94-01
SPOILER ELEVATOR COMPUTER (SEC) 3 (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 27-94-00-861-055-A
Subtask 27-94-00-040-051-A
Subtask 27-94-00-860-059-A
[Rev.10 from 2021]
2026.03.31 23:59:37 UTC
Deactivation of the Spoiler Elevator Computer 3 (SEC)
1. Reason for the Job
MMEL 27-94-03P
SEC 3 (FAA ONLY)
MMEL 27-94-01
SPOILER ELEVATOR COMPUTER (SEC) 3 (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 27-94-00-861-055-A
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 27-94-00-865-057-A (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | FLIGHT CONTROLS/SEC3/SPLY | 21CE3 | Q19 |
Subtask 27-94-00-040-051-A
A. Deactivation of the Spoiler Elevator Computer 3 (SEC)
5. Close-up| ACTION | RESULT |
|---|---|
1.On the overhead panel, on the FLT CTL panel 24VU:
| On the overhead panel, on the FLT CTL panel 24VU:
|
2.On the circuit breaker panel 121VU:
NOTE: The spoilers associated to the SEC3 will be inoperative. | |
Subtask 27-94-00-860-059-A
A. Put the aircraft back to its initial configuration.
(1) On the overhead panel, on the FLT CTL panel 24VU, put a WARNING NOTICE(S) on the pushbutton switch SEC3.
(2) Make an entry in the logbook.
(3) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) On the overhead panel, on the FLT CTL panel 24VU, put a WARNING NOTICE(S) on the pushbutton switch SEC3.
(2) Make an entry in the logbook.
(3) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).