Reactivation of the Channel 1 of the Rudder Trim Actuator
TASK 27-22-00-440-001-A
Reactivation of the Channel 1 of the Rudder Trim Actuator
1. Reason for the Job
MMEL 22-60-01A
FAC 1
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 27-22-00-860-060-A
Subtask 27-22-00-440-050-A
Subtask 27-22-00-410-054-A
[Rev.10 from 2021]
2026.03.31 23:48:51 UTC
Reactivation of the Channel 1 of the Rudder Trim Actuator
1. Reason for the Job
MMEL 22-60-01A
FAC 1
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 27-22-00-860-060-A
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 27-22-00-010-053-A (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
B. Get access to the avionics compartment.
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the access door 824.
(2) Open the access door 824.
Subtask 27-22-00-865-056-A (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the access door 824.
(2) Open the access door 824.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AUTO FLT/FAC1/28VDC | 5CC1 | B04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AUTO FLT/FAC1/28VDC | 5CC1 | H10 |
Subtask 27-22-00-440-050-A
A. Reactivation of the Channel 1 of the Rudder Trim Actuator
(1) On the panel 187VU, install the relay 7CC1
(2) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
5CC1.
Subtask 27-22-00-810-050-A (1) On the panel 187VU, install the relay 7CC1
(2) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
5CC1.
B. Do the trouble shooting of the rudder trim actuator you deactivated.
5. Close-upSubtask 27-22-00-410-054-A
A. Close Access
(1) Close the access door 824.
(2) Remove the access platform(s).
Subtask 27-22-00-862-055-A (1) Close the access door 824.
(2) Remove the access platform(s).
B. Put the aircraft back to its initial configuration.
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).