Installation of the Pressure Reducer
TASK 26-23-18-400-001-A
Installation of the Pressure Reducer
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 26-23-18-010-051-A ** ON A/C NOT FOR ALL
Subtask 26-23-18-720-051-A ** ON A/C NOT FOR ALL
Subtask 26-23-18-865-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 06:44:55 UTC
Installation of the Pressure Reducer
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | Torque wrench: range to between 3 and 2.5 m.daN (22.12 and 18.44 lbf.ft ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.03FAB1) | Mineral Oil base Grease-- Vaseline or Petrolatum - |
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 132MW, 825 |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 5 | O-RING | AIPC 26-23-02-03-200 |
| 2 | TAB WASHER | AIPC 26-23-02-04-070 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-54-12-000-003-A | Removal of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 25-54-12-400-003-A | Installation of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 26-23-00-200-003-A | Remove the Pressure Reducer for in-shop Functional Check Including Check of Fire Extinguishing Lines for Leakage and Obstruction |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 26-23-18-010-051-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001)
(2) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position below the forward cargo-compartment door 825.
(3) Make sure that the forward cargo-compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(4) Make sure that the CARGO COMPT LIGHT switch 6LU is in the ON position.
(5) Make sure that the protection panel 132MW is removed (Ref. AMM TASK 25-54-12-000-003).
Subtask 26-23-18-865-053-A ** ON A/C NOT FOR ALL (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001)
(2) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position below the forward cargo-compartment door 825.
(3) Make sure that the forward cargo-compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
(4) Make sure that the CARGO COMPT LIGHT switch 6LU is in the ON position.
(5) Make sure that the protection panel 132MW is removed (Ref. AMM TASK 25-54-12-000-003).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C05 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C04 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C03 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/CARGO/FIRE/EXTIG | 1WX | T19 |
Subtask 26-23-18-720-051-A ** ON A/C NOT FOR ALL
A. Functional Test of the Pressure Reducer
(1) Before you install the pressure reducer the functional test must be done.
Subtask 26-23-18-420-051-A ** ON A/C NOT FOR ALL (1) Before you install the pressure reducer the functional test must be done.
NOTE: If the pressure reducer was already tested in a short timebefore this functional test, it is not necessary to test it again.
(a) Send the pressure reducer to the workshop. B. Installation of the Pressure Reducer
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the blanking plugs from the disconnected line ends.
(4) Remove the blanking plugs from the ports of the pressure reducer (4).
(5) Apply grease as follows:
(6) Install the pressure reducer (4):
(b) Install the new AIPC 26-23-02-04-070 TAB WASHER (2) and the nut (1).
(c) TORQUE the nut (1) to between 3 and 2.5 m.daN (22.12 and 18.44 lbf.ft )
.
(d) Safety the nut (1) with the tab washer (2).
(7) Install the new AIPC 26-23-02-03-200 O-RING (5) on the unions (6).
(8) Install the unions (6) on the pressure reducer (4) and tighten.
(9) Connect the pipes (8) and tighten the nuts (7).
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
Subtask 26-23-18-210-052-A ** ON A/C NOT FOR ALL NOTE: The installation procedure is the same for the pressure reducers 5014WM and 5015WM.
(1) Clean the component interfaces and the adjacent area.(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the blanking plugs from the disconnected line ends.
(4) Remove the blanking plugs from the ports of the pressure reducer (4).
(5) Apply grease as follows:
CAUTION:
APPLY A SMALL QUANTITY OF THE CORRECT GREASE TO THE MALE THREADS OF THE CONNECTIONS. THIS WILL PREVENT DAMAGE TO THE THREADS.
MAKE SURE THAT GREASE DOES NOT GO INTO THE PIPES. GREASE IN THE PIPES CAN CAUSE A MALFUNCTION OF THE SYSTEM.
(a) Apply a small quantity of Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.03FAB1) to the male threads of the pressure reducer (4). (6) Install the pressure reducer (4):
WARNING:
MAKE SURE THAT YOU INSTALL THE PRESSURE REDUCER IN THE CORRECT DIRECTION OF FLOW (REFER TO THE ARROW ON THE PRESSURE REDUCER HOUSING). IF YOU DO NOT OBEY THIS INSTRUCTION, DAMAGE TO EQUIPMENT AND A MALFUNCTION OF THE FIRE EXTINGUISHING SYSTEM CAN OCCUR.
(a) Put the pressure reducer (4) in its installation position on the bracket (3). (b) Install the new AIPC 26-23-02-04-070 TAB WASHER (2) and the nut (1).
(c) TORQUE the nut (1) to between 3 and 2.5 m.daN (22.12 and 18.44 lbf.ft )
. (d) Safety the nut (1) with the tab washer (2).
(7) Install the new AIPC 26-23-02-03-200 O-RING (5) on the unions (6).
(8) Install the unions (6) on the pressure reducer (4) and tighten.
(9) Connect the pipes (8) and tighten the nuts (7).
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(10) Safety the unions (6) with lockwire C. Functional Check
(1) Do a check of the pressure reducer in the flow metering device and check of the cargo-compartment fire-extinguishing distribution-piping for leakage and blockages (Ref. AMM TASK 26-23-00-200-003).
5. Close-up(1) Do a check of the pressure reducer in the flow metering device and check of the cargo-compartment fire-extinguishing distribution-piping for leakage and blockages (Ref. AMM TASK 26-23-00-200-003).
Subtask 26-23-18-865-054-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 26-23-18-410-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C05 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CARGO FIRE/EXTIG/BTL2 | 8WX | C04 |
| 49VU | AIR COND/CARGO/FIRE/EXTIG/BTL1 | 1WX | C03 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/CARGO/FIRE/EXTIG | 1WX | T19 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the protection panel 132MW (Ref. AMM TASK 25-54-12-400-003).
(3) In the forward cargo-compartment, set the CARGO COMPT LIGHT switch 6LU to OFF.
(4) Close the forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
Subtask 26-23-18-860-053-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the protection panel 132MW (Ref. AMM TASK 25-54-12-400-003).
(3) In the forward cargo-compartment, set the CARGO COMPT LIGHT switch 6LU to OFF.
(4) Close the forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
C. Put the aircraft back to its initial configuration.
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
Pressure Reducer (5014WM, 5015WM)