Installation of the Halon Filter


TASK 26-23-14-400-002-A
Installation of the Halon Filter


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 150
ZONE: 160
ZONE: 170
FIN: 5040WM ** ON A/C NOT FOR ALL
FIN: 5041WM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Consumable Materials
REFERENCE
DESIGNATION
(Material No.03FAB1)
Mineral Oil base Grease-- Vaseline or Petrolatum -
(Material No.14QFB1)
Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
150
AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT
160
BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT
170
AFT CAB U/FLOOR COMPT AFT BHD OF BULK
161DW, 826
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
2
ORING
AIPC 26-23-84-05-390
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 25-55-12-000-001-A
Removal of the Aft Cargo-Compartment Partition at FR65
TASK 25-55-12-400-001-A
Installation of the Aft Cargo-Compartment Partition at FR65
TASK 26-23-00-200-004-A
Check of the Fire Extinguishing Lines of the Two Fire Extinguisher Bottles for Leakage and Blockage
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 26-23-14-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 26-23-14-010-060-C ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Make sure that the aft cargo-compartment door 826 is open (Ref. AMM TASK 52-30-00-860-001).
   (2) Make sure that the CARGO COMPT LIGHT switch 8LU is in the ON position.
   (3) Make sure that the partition panel 161DW is removed (Ref. AMM TASK 25-55-12-000-001).
Subtask 26-23-14-865-059-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/CARGO FIRE/EXTIG/BTL28WXC04
49VUAIR COND/CARGO FIRE/EXTIG/BTL11WXC03
4. Procedure
Subtask 26-23-14-420-053-F ** ON A/C NOT FOR ALL
A. Installation of the Halon Filter
NOTE: The installation procedure is the same for the halon filters 5040WM and 5041WM.
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the blanking plugs from the disconnected line ends.
   (4) Remove the blanking plugs from the halon filter (1).
   (5) Apply grease as follows:
CAUTION: APPLY A SMALL QUANTITY OF THE CORRECT GREASE TO THE MALE THREADS OF THE CONNECTIONS. THIS WILL PREVENT DAMAGE TO THE THREADS. MAKE SURE THAT GREASE DOES NOT GO INTO THE PIPES. GREASE IN THE PIPES CAN CAUSE A MALFUNCTION OF THE SYSTEM.
     (a) Apply a small quantity of Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.03FAB1) to the male threads.
   (6) Put the halon filter (1) in position on the bracket (8).
   (7) Install the washers (6), the screws (7) and tighten them.
   (8) Install the new AIPC 26-23-84-05-390 ORING (2) on the unions (3).
   (9) Install the unions (3) on the halon filter (1) and tighten them.
   (10) Install the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Safety the unions (3) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (11) Connect the pipes (5) to the halon filter (1) and tighten the nuts (4).
Subtask 26-23-14-210-054-A ** ON A/C NOT FOR ALL 5. Close-up
Subtask 26-23-14-865-060-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/CARGO FIRE/EXTIG/BTL28WXC04
49VUAIR COND/CARGO FIRE/EXTIG/BTL11WXC03
Subtask 26-23-14-410-056-C ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the partition panel 161DW (Ref. AMM TASK 25-55-12-400-001).
   (3) Set the CARGO COMPT LIGHT switch 8LU to the OFF position.
   (4) Close the aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002).
Subtask 26-23-14-862-052-A ** ON A/C NOT FOR ALL
C. Put the aircraft back to its initial configuration.
   (1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).