Installation of the APU Fire-Extinguisher Discharge-Outlet and Tubing
TASK 26-22-41-400-803-A
Installation of the APU Fire-Extinguisher Discharge-Outlet and Tubing
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 26-22-41-860-059-A
Subtask 26-22-41-420-058-A
Subtask 26-22-41-865-065-A
[Rev.10 from 2021]
2026.03.31 23:45:40 UTC
Installation of the APU Fire-Extinguisher Discharge-Outlet and Tubing
WARNING:
BE VERY CAREFUL WHEN YOU MOVE A FULL FIRE EXTINGUISHER BOTTLE. A SUDDEN OR HEAVY SHOCK TO A FULL BOTTLE CAN CAUSE UNWANTED DISCHARGE AND INJURY TO PERSONS.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 314AR |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 9 | PACKING | AIPC 26-22-04-01-016 |
| 3 | O-RINGS | AIPC 26-22-04-02-050 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 26-22-42-400-001-A | Installation of the Fire-Extinguisher Bottle Cartridge |
| TASK 52-41-23-010-801-A | Opening of Access Door 314AR |
| TASK 52-41-23-410-801-A | Closing of Access Door 314AR |
Subtask 26-22-41-860-059-A
A. Aircraft Maintenance Configuration
(1) Make sure that the WARNING NOTICE(S) is installed on the overhead panel 25VU to tell the persons not to operate the APU.
Subtask 26-22-41-865-064-A (1) Make sure that the WARNING NOTICE(S) is installed on the overhead panel 25VU to tell the persons not to operate the APU.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 26-22-41-010-060-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | APU/FIRE AND OVHT/DET/LOOP B | 2WG | L44 |
| 121VU | APU/FIRE AND OVHT/DET/LOOP A | 1WG | L43 |
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
| 121VU | APU/FIRE/LP VALVE/NORM | 4WF | M42 |
| 121VU | APU/FIRE/LP VALVE/STBY | 3WF | M41 |
C. Aircraft Maintenance Configuration
(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below maintenance door 314AR.
(3) Make sure that access door 314AR is open and safetied in the open position.
(Ref. AMM TASK 52-41-23-010-801).
(4) Make sure that the light switch is set to on.
4. ProcedureWARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
(1) Put on and attach a safety harness before you start work in the work area(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below maintenance door 314AR.
(3) Make sure that access door 314AR is open and safetied in the open position.
(Ref. AMM TASK 52-41-23-010-801).
(4) Make sure that the light switch is set to on.
Subtask 26-22-41-420-058-A
A. Installation of the APU Fire-Extinguisher Discharge-Outlet (4015WM) and Tubing for Meggitt Assembly
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Installation of the discharge outlet.
(a) Remove the PLUG-BLANKING from each disconnected line end.
(b) Install a new AIPC 26-22-04-01-016 PACKING (9) on the discharge outlet (7).
(c) Install the discharge outlet (7) in the fire-extinguisher bottle outlet (10).
(d) Do not fully tighten the discharge outlet (7) at this step.
(5) Installation of the spray tubing.
(a) Install the new AIPC 26-22-04-02-050 O-RINGS (3) and the ring-retainings (2) on the spray tubing (6) and on the discharge outlet (7).
(b) Make sure that the O-ring (3) is correctly installed in the groove of the discharge outlet (7).
(c) Loosely install the bushing (4).
(d) Put the spray tubing (6) in position and loosely install the nuts (1).
(e) Adjust the spray tubing (6) and the discharge outlet (7) to each other.
(f) Install the clamp (5).
(g) Make sure that the spray tubing (6) is aligned with the discharge outlet (7).
(h) Tighten the nuts (1).
(i) Safety the nuts (1) with14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(6) TORQUE the swivel nut (8) to between 7.5 and 6.1 m.daN (55.31 and 44.99 lbf.ft )
.
(7) Safety the swivel nut (8) with14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(8) Install the fire extinguisher cartridge (Ref. AMM TASK 26-22-42-400-001).
Subtask 26-22-41-420-059-A (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Installation of the discharge outlet.
(a) Remove the PLUG-BLANKING from each disconnected line end.
(b) Install a new AIPC 26-22-04-01-016 PACKING (9) on the discharge outlet (7).
(c) Install the discharge outlet (7) in the fire-extinguisher bottle outlet (10).
(d) Do not fully tighten the discharge outlet (7) at this step.
(5) Installation of the spray tubing.
(a) Install the new AIPC 26-22-04-02-050 O-RINGS (3) and the ring-retainings (2) on the spray tubing (6) and on the discharge outlet (7).
(b) Make sure that the O-ring (3) is correctly installed in the groove of the discharge outlet (7).
(c) Loosely install the bushing (4).
(d) Put the spray tubing (6) in position and loosely install the nuts (1).
(e) Adjust the spray tubing (6) and the discharge outlet (7) to each other.
(f) Install the clamp (5).
(g) Make sure that the spray tubing (6) is aligned with the discharge outlet (7).
(h) Tighten the nuts (1).
(i) Safety the nuts (1) with
(6) TORQUE the swivel nut (8) to between 7.5 and 6.1 m.daN (55.31 and 44.99 lbf.ft )
. (7) Safety the swivel nut (8) with
(8) Install the fire extinguisher cartridge (Ref. AMM TASK 26-22-42-400-001).
B. Installation of the APU Fire-Extinguisher Discharge-Outlet (4015WM) and Tubing for Kidde Assembly
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Installation of the discharge outlet.
(a) Remove the PLUG-BLANKING from each disconnected line end.
(b) Install the discharge outlet (7) in the fire-extinguisher bottle outlet (9).
(c) Do not fully tighten the discharge outlet (7) at this step.
(5) Installation of the spray tubing.
(a) Install the new AIPC 26-22-04-02-050 O-RINGS (3) and the ring-retainings (2) on the spray tubing (6) and on the discharge outlet (7).
(b) Make sure that the O-ring (3) is correctly installed in the groove of the discharge outlet (7).
(c) Loosely install the bushing (4).
(d) Put the spray tubing (6) in position and loosely install the nuts (1).
(e) Adjust the spray tubing (6) and the discharge outlet (7) to each other.
(f) Install the clamp (5).
(g) Make sure that the spray tubing (6) is aligned with the discharge outlet (7).
(h) Tighten the nuts (1).
(i) Safety the nuts (1) with14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(6) TORQUE the swivel nut (8) to between 4.0 and 3.4 m.daN (29.50 and 25.07 lbf.ft )
.
(7) Safety the swivel nut (8) with14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(8) Install the fire extinguisher cartridge (Ref. AMM TASK 26-22-42-400-001).
5. Close-up(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Installation of the discharge outlet.
(a) Remove the PLUG-BLANKING from each disconnected line end.
(b) Install the discharge outlet (7) in the fire-extinguisher bottle outlet (9).
(c) Do not fully tighten the discharge outlet (7) at this step.
(5) Installation of the spray tubing.
(a) Install the new AIPC 26-22-04-02-050 O-RINGS (3) and the ring-retainings (2) on the spray tubing (6) and on the discharge outlet (7).
(b) Make sure that the O-ring (3) is correctly installed in the groove of the discharge outlet (7).
(c) Loosely install the bushing (4).
(d) Put the spray tubing (6) in position and loosely install the nuts (1).
(e) Adjust the spray tubing (6) and the discharge outlet (7) to each other.
(f) Install the clamp (5).
(g) Make sure that the spray tubing (6) is aligned with the discharge outlet (7).
(h) Tighten the nuts (1).
(i) Safety the nuts (1) with
(6) TORQUE the swivel nut (8) to between 4.0 and 3.4 m.daN (29.50 and 25.07 lbf.ft )
. (7) Safety the swivel nut (8) with
(8) Install the fire extinguisher cartridge (Ref. AMM TASK 26-22-42-400-001).
Subtask 26-22-41-865-065-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 26-22-41-410-055-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | APU/FIRE AND OVHT/DET/LOOP B | 2WG | L44 |
| 121VU | APU/FIRE AND OVHT/DET/LOOP A | 1WG | L43 |
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
| 121VU | APU/FIRE/LP VALVE/NORM | 4WF | M42 |
| 121VU | APU/FIRE/LP VALVE/STBY | 3WF | M41 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Set the light switch to off.
(3) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Set the light switch to off.
(3) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).
Extinguisher Discharge-Outlet and Tubing (Meggitt Bottle)