Operational Test of the Supplementary Medical Equipment Supply
TASK 25-67-00-710-801-A
Operational Test of the Supplementary Medical Equipment Supply
1. Reason for the Job
This operational test makes sure that the supplementary medical equipment supply works correctly and supplies the correct voltage values.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 25-67-00-860-050-A ** ON A/C NOT FOR ALL
Subtask 25-67-00-710-050-B ** ON A/C NOT FOR ALL
Subtask 25-67-00-860-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:41:45 UTC
Operational Test of the Supplementary Medical Equipment Supply
1. Reason for the Job
This operational test makes sure that the supplementary medical equipment supply works correctly and supplies the correct voltage values.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 2 | MULTIMETER - STANDARD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-67-00-00 | SUPPLEMENTARY MEDICAL EQUIPMENT - DESCRIPTION AND OPERATION |
Subtask 25-67-00-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) For the location of this component, refer to Para. Component Location (Ref. AMM D/O 25-67-00-00).
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-67-00-865-050-A ** ON A/C NOT FOR ALL (1) For the location of this component, refer to Para. Component Location (Ref. AMM D/O 25-67-00-00).
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | MEDICAL OUTLET-AC | 7MF | B08 |
| 2001VU | MEDICAL OUTLET-DC | 6MF | B07 |
Subtask 25-67-00-710-050-B ** ON A/C NOT FOR ALL
A. Operational Test (115 VAC)
Subtask 25-67-00-710-053-B ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| 1.On the related medical outlet: | On the multimeter: |
|
|
| |
B. Operational Test (28 VDC)
5. Close-up| ACTION | RESULT |
|---|---|
| 1.On the related medical outlet: | On the multimeter: |
|
|
| |
Subtask 25-67-00-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).