Removal of the Programming Dongle
TASK 25-65-35-000-003-A
Removal of the Programming Dongle
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-65-35-861-052-B ** ON A/C NOT FOR ALL Subtask 25-65-35-010-053-B ** ON A/C NOT FOR ALL
Subtask 25-65-35-020-052-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:41:23 UTC
Removal of the Programming Dongle
ZONE: 200
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| 261BC |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 25-23-42-000-002-A | Removal of the Ceiling Panels - Aft Utility Area |
Subtask 25-65-35-861-052-B ** ON A/C NOT FOR ALL Subtask 25-65-35-010-053-B ** ON A/C NOT FOR ALL
B. Get access to the Programming Dongle
(1) Remove the ceiling panel 261BC (Ref. AMM TASK 25-23-42-000-002).
4. Procedure(1) Remove the ceiling panel 261BC (Ref. AMM TASK 25-23-42-000-002).
Subtask 25-65-35-020-052-B ** ON A/C NOT FOR ALL
A. Removal of the Programming Dongle 141MX
(1) Set the ON/OFF/ARM switch (6) to the OFF position.
(2) Disconnect the electrical connector (3) or programming-dongle (2) from the connector (7) of the ELT (4).
(3) Disconnect the electrical connector (1) from the bracket (5).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(1) Set the ON/OFF/ARM switch (6) to the OFF position.
(2) Disconnect the electrical connector (3) or programming-dongle (2) from the connector (7) of the ELT (4).
(3) Disconnect the electrical connector (1) from the bracket (5).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
DONGLE (141 MX)