General Visual Inspection of External ELT Antenna
TASK 25-65-00-210-802-A
General Visual Inspection of External ELT Antenna
Refer to the MPD TASK: 256535-04
GENERAL VISUAL INSPECTION OF EXTERNAL ELT ANTENNA
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 25-65-00-941-052-A ** ON A/C NOT FOR ALL
Subtask 25-65-00-210-060-A ** ON A/C NOT FOR ALL
Subtask 25-65-00-942-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:41:11 UTC
General Visual Inspection of External ELT Antenna
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 256535-04
GENERAL VISUAL INSPECTION OF EXTERNAL ELT ANTENNA
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 6M (20 FT) |
| 98L12003001000 | 1 | HARNESS,SAFETY |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 260 | AFT CABIN UTILITY AREA |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-65-14-000-001-A | Removal of the Emergency Locator Transmitter (ELT) Antenna |
| TASK 25-65-14-400-001-A | Installation of the Emergency Locator Transmitter (ELT) Antenna |
Subtask 25-65-00-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
Subtask 25-65-00-010-073-A ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
(1) Put on and attach the 98L12003001000 HARNESS,SAFETY before you start work in the work area. B. Get Access
(1) Put the ACCESS PLATFORM 6M (20 FT) in position.
Subtask 25-65-00-160-050-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 6M (20 FT) in position.
C. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If necessary, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If necessary, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) .
Subtask 25-65-00-210-060-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a general visual inspection of the external emergency-locator-transmitter (ELT) antenna (1) and make sure that there are no cracks or corrosion around the ELT antenna basis.
(2) In case of cracks or corrosion, remove the ELT antenna (1) (Ref. AMM TASK 25-65-14-000-001) and install a serviceable ELT antenna (1) (Ref. AMM TASK 25-65-14-400-001).
5. Close-up(1) Do a general visual inspection of the external emergency-locator-transmitter (ELT) antenna (1) and make sure that there are no cracks or corrosion around the ELT antenna basis.
(2) In case of cracks or corrosion, remove the ELT antenna (1) (Ref. AMM TASK 25-65-14-000-001) and install a serviceable ELT antenna (1) (Ref. AMM TASK 25-65-14-400-001).
Subtask 25-65-00-942-052-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Remove the ACCESS PLATFORM 6M (20 FT).
(2) Remove all the fixtures, tools, test and support equipment used during this procedure.
(1) Remove the ACCESS PLATFORM 6M (20 FT).
(2) Remove all the fixtures, tools, test and support equipment used during this procedure.
ELT Antenna