Visual Check of the Pressure Indication of the Inflation Reservoir - Escape-Slides at Doors 2/3
TASK 25-62-00-040-002-A
Visual Check of the Pressure Indication of the Inflation Reservoir - Escape-Slides at Doors 2/3
1. Reason for the Job
A. Referenced Information
3. Job Set-up
Subtask 25-62-00-010-065-A ** ON A/C NOT FOR ALL
Subtask 25-62-00-210-064-A ** ON A/C NOT FOR ALL
Subtask 25-62-00-410-060-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:40:00 UTC
Visual Check of the Pressure Indication of the Inflation Reservoir - Escape-Slides at Doors 2/3
1. Reason for the Job
NOTE: This deactivation task is not related to an AFM-CDL/MMEL item.
2. Job Set-up InformationA. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-62-49-000-001-A | Removal of the Escape-Slide Inflation Reservoir |
| TASK 25-62-49-400-001-A | Installation of the Escape-Slide Inflation Reservoir |
Subtask 25-62-00-010-065-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Remove/open the access panel to the escape-slide inflation reservoir (Ref. AMM TASK 25-62-49-000-001).
4. Procedure(1) Remove/open the access panel to the escape-slide inflation reservoir (Ref. AMM TASK 25-62-49-000-001).
Subtask 25-62-00-210-064-A ** ON A/C NOT FOR ALL
A. Visual Inspection
(1) Make sure that the pressure gage (1) (referred to as gage) shows the correct pressure.
1 Let the temperature conditions become stable, then examine the gage (1) again.
2 If the gage needle continues to show an incorrect indication, replace the inflation reservoir (Ref. AMM TASK 25-62-49-000-001).
Subtask 25-62-00-210-064-B ** ON A/C NOT FOR ALL (1) Make sure that the pressure gage (1) (referred to as gage) shows the correct pressure.
NOTE: There are two different types of gage (1) (MODEL A and MODEL B). MODEL A has a green cursor which is temperature sensitive. MODEL B has a needle with an internal mechanism, which is temperature sensitive. They can give temporary low pressure indications when there are sudden temperature changes (from a cold to a warm environment). The cursor/needle moves to changes in temperature faster than the gas can expand in the inflation reservoir.
(a) The permitted indications for MODEL A are as follows: - The needle in AREA A (green cursor width) shows that the pressure indication is correct.
- The needle in AREA B, which is half the range of AREA A, shows a permitted indication, because of sudden temperature changes.
- The GREEN BAND shows a correct indication
- AREA B, which has a range equal to AREA A, shows a permitted indication because of sudden temperature changes.
1 Let the temperature conditions become stable, then examine the gage (1) again.
2 If the gage needle continues to show an incorrect indication, replace the inflation reservoir (Ref. AMM TASK 25-62-49-000-001).
A. Visual Inspection
(1) Make sure that the pressure gage (1) (referred to as gage) shows the correct pressure.
1 Let the temperature conditions become stable, then examine the gage (1) again.
2 If the gage needle continues to show an incorrect indication, replace the inflation reservoir (Ref. AMM TASK 25-62-49-000-001).
5. Close-up(1) Make sure that the pressure gage (1) (referred to as gage) shows the correct pressure.
NOTE: The gage (1) has a needle with an internal mechanism, which is temperature sensitive. They can give temporary low pressure indications when there are sudden temperature changes (from a cold to a warm environment). The needle moves to changes in temperature faster than the gas can expand in the inflation reservoir.
(a) The permitted indications are as follows: - The GREEN BAND shows a correct indication
- AREA B, which has a range equal to AREA A, shows a permitted indication because of sudden temperature changes.
1 Let the temperature conditions become stable, then examine the gage (1) again.
2 If the gage needle continues to show an incorrect indication, replace the inflation reservoir (Ref. AMM TASK 25-62-49-000-001).
Subtask 25-62-00-410-060-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install/Close the inflation reservoir access-panel (Ref. AMM TASK 25-62-49-400-001).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install/Close the inflation reservoir access-panel (Ref. AMM TASK 25-62-49-400-001).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Inflation Reservoir Pressure-Gage