Installation of the Door Microswitch of the Space Flex Lavatory
TASK 25-45-33-400-802-A
Installation of the Door Microswitch of the Space Flex Lavatory
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 25-45-33-860-052-A ** ON A/C NOT FOR ALL
Subtask 25-45-33-210-051-A ** ON A/C NOT FOR ALL
Subtask 25-45-33-862-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:33:09 UTC
Installation of the Door Microswitch of the Space Flex Lavatory
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 25-45-33-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-45-33-865-055-A ** ON A/C NOT FOR ALL (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LIGHT-LAV | 1LQ | J01 |
| 2001VU | LAVATORY AFT-OCCUPIED | 11WJ | B04 |
Subtask 25-45-33-210-051-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
(1) Clean the component interfaces and the adjacent area.
(2) Do a visual inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
Subtask 25-45-33-420-051-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do a visual inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
B. Installation of the Door Microswitch of the Space Flex Lavatory
(1) When you connect/install the components, refer to the match marks made during the removal procedure.
(2) Carefully put the supports (3) together with the door microswitches (2) in position, then install the screws (4).
(3) Tighten the screws (4).
(4) Make sure that the work area is clean and clear of tools and other items.
(5) Close the lavatory doors (1).
Subtask 25-45-33-865-054-A ** ON A/C NOT FOR ALL (1) When you connect/install the components, refer to the match marks made during the removal procedure.
(2) Carefully put the supports (3) together with the door microswitches (2) in position, then install the screws (4).
(3) Tighten the screws (4).
(4) Make sure that the work area is clean and clear of tools and other items.
(5) Close the lavatory doors (1).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LIGHT-LAV | 1LQ | J01 |
| 2001VU | LAVATORY AFT-OCCUPIED | 11WJ | B04 |
Subtask 25-45-33-862-051-A ** ON A/C NOT FOR ALL
Door Microswitch of the Space Flex Lavatory