Installation of the Access Door on the Lavatory Front Wall
TASK 25-45-18-400-001-A
Installation of the Access Door on the Lavatory Front Wall
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 25-45-18-860-050-A
Subtask 25-45-18-210-050-A
Subtask 25-45-18-862-050-A
[Rev.10 from 2021]
2026.03.31 23:36:05 UTC
Installation of the Access Door on the Lavatory Front Wall
ZONE: 200
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 25-45-18-860-050-A
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
4. Procedure(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-45-18-210-050-A
A. Preparation for Installation
(1) Clean the component interfaces and the adjacent area.
(2) Make sure that the parts retained from the removed component are clean and in the correct condition.
(3) Do an inspection of the component interfaces and the adjacent area.
Subtask 25-45-18-420-050-A (1) Clean the component interfaces and the adjacent area.
(2) Make sure that the parts retained from the removed component are clean and in the correct condition.
(3) Do an inspection of the component interfaces and the adjacent area.
B. Installation of the Access Door on the Lavatory Front Wall
(1) Put the section (3) and the access door (1) in position on the lavatory front wall.
(2) Install the screws (2).
(3) Close the access door (1).
Subtask 25-45-18-710-050-A (1) Put the section (3) and the access door (1) in position on the lavatory front wall.
(2) Install the screws (2).
(3) Close the access door (1).
C. Operational Test of the Access Door on the Lavatory Front Wall
(1) Open and close the access door (1) and make sure the door locks correctly in the closed position, if necessary adjust as follows;
(a) Open the access door (1), loosen the screws (2) and adjust the door until it locks correctly.
(b) Tighten the screws (2).
(c) Close the access door (1).
5. Close-up(1) Open and close the access door (1) and make sure the door locks correctly in the closed position, if necessary adjust as follows;
(a) Open the access door (1), loosen the screws (2) and adjust the door until it locks correctly.
(b) Tighten the screws (2).
(c) Close the access door (1).
Subtask 25-45-18-862-050-A
Access Door on the Lavatory Front Wall