Installation of the Waste Chute Flap
TASK 25-45-15-400-001-A
Installation of the Waste Chute Flap
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-45-15-860-050-A
Subtask 25-45-15-210-050-A
Subtask 25-45-15-862-050-A
[Rev.10 from 2021]
2026.03.31 23:35:53 UTC
Installation of the Waste Chute Flap
ZONE: 200
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | GAGE - FEELER |
| No specific | Torque wrench: range to between 0.38 and 0.22 m.daN (33.63 and 19.47 lbf.in ) ![]() |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 25-45-15-860-050-A
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
4. Procedure(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-45-15-210-050-A
A. Preparation for Installation
(1) Clean the component interfaces and the adjacent area.
(2) Make sure that the parts retained from the removed component are clean and in the correct condition.
(3) Do an inspection of the component interfaces and the adjacent area.
Subtask 25-45-15-420-050-B (1) Clean the component interfaces and the adjacent area.
(2) Make sure that the parts retained from the removed component are clean and in the correct condition.
(3) Do an inspection of the component interfaces and the adjacent area.
B. Installation of the Waste Chute Flap (Plastic)
(1) Get access from under the wash basin and put the waste chute flap (1) in position on the hinge (4).
(2) Install the screws (6) and the washers (5). TORQUE the screws to between 0.38 and 0.22 m.daN (33.63 and 19.47 lbf.in )
.
(3) Use the GAGE - FEELER and measure the dimension B between the waste chute flap (1) and the wash basin, this must be 1.0 mm (0.0394 in.). If necessary, adjust as follows:
(a) Loosen the screws (6) and adjust the waste chute flap (1) until you get dimension B.
(b) TORQUE tighten the screws (6) to between 0.38 and 0.22 m.daN (33.63 and 19.47 lbf.in )
.
(4) Install the waste container (3) and close the access door (2).
(5) Push the waste chute flap (1) and make sure it operates correctly.
5. Close-up(1) Get access from under the wash basin and put the waste chute flap (1) in position on the hinge (4).
(2) Install the screws (6) and the washers (5). TORQUE the screws to between 0.38 and 0.22 m.daN (33.63 and 19.47 lbf.in )
. (3) Use the GAGE - FEELER and measure the dimension B between the waste chute flap (1) and the wash basin, this must be 1.0 mm (0.0394 in.). If necessary, adjust as follows:
(a) Loosen the screws (6) and adjust the waste chute flap (1) until you get dimension B.
(b) TORQUE tighten the screws (6) to between 0.38 and 0.22 m.daN (33.63 and 19.47 lbf.in )
. (4) Install the waste container (3) and close the access door (2).
(5) Push the waste chute flap (1) and make sure it operates correctly.
Subtask 25-45-15-862-050-A
Waste Chute Flap (Plastic)