W DOC AIRBUS | AMM A320F

Installation of the Soap Dispenser


TASK 25-45-14-400-001-A
Installation of the Soap Dispenser


ZONE: 200
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
FUNNEL
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.14SBA1)
Textile-Lint free Cotton -
No specific
liquid soap
No specific
liquid soap PN 83-182 - Supplier CWF Chemie Frankfurt GmbH.
No specific
weak liquid soap
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
F Liquid Soap Dispenser ** ON A/C NOT FOR ALL
F Liquid Soap Dispenser ** ON A/C NOT FOR ALL
F Liquid Soap Dispenser ** ON A/C NOT FOR ALL
F Fill Soap Dispenser ** ON A/C NOT FOR ALL
F Fill Soap Dispenser ** ON A/C NOT FOR ALL
F Soap Dispenser ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 25-45-14-860-050-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
4. Procedure
Subtask 25-45-14-210-050-A
A. Preparation for Installation
   (1) Clean the component interfaces and the adjacent area.
   (2) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (3) Do an inspection of the component interfaces and the adjacent area.
Subtask 25-45-14-420-050-A ** ON A/C NOT FOR ALL
B. Installation of the Soap Dispenser
F Liquid Soap Dispenser ** ON A/C NOT FOR ALL
   (1) Install the spout (2) together with the shank (3), the washer (4) and the rubber washer (5) on the wash basin assembly (10).
   (2) Install the lock-washer (6), the rubber washer (7) and the lock-nut (8).
   (3) Install the soap container (9).
   (4) Close the access door (1).
Subtask 25-45-14-420-050-C ** ON A/C NOT FOR ALL
B. Installation of the Soap Dispenser
F Liquid Soap Dispenser ** ON A/C NOT FOR ALL
   (1) Install the new filter (10) on the soap container (11) as necessary.
   (2) Install the piston (3) together with the shank (6) and the spring (4) on the wash basin assembly (5).
   (3) Install the tooth-lock washer (7), the rubber washer (8) and the retaining-nut (9).
   (4) Install the soap container (11).
   (5) Replace the placard (2) as necessary.
   (6) Close the access door (1).
Subtask 25-45-14-420-050-G ** ON A/C NOT FOR ALL
B. Installation of the Soap Dispenser
F Liquid Soap Dispenser ** ON A/C NOT FOR ALL
   (1) Put the soap outlet (2) and the seal (3) in position on the wash basin assembly and install and tighten the nut (4).
   (2) Install the knurled nut (5) and the soap bottle (6).
   (3) Install the pump assembly (1) in the soap outlet (2) and tighten it clockwise with your fingers.
   (4) Make sure that the work area is clean and clear of tools and other items.
   (5) Close the access door.
Subtask 25-45-14-613-050-A ** ON A/C NOT FOR ALL
CAUTION: DO NOT USE INDUSTRIAL HAND CLEANERS, NATURAL SOAPS AND CLEANING AGENTS THAT CONTAIN ABRASIVES, SOLVENTS OR A LARGE PROPORTION OF DISINFECTANT. THESE MATERIALS CAN CAUSE THE PUMP MECHANISM TO WEAR MORE QUICKLY.
C. Fill the Soap Dispenser
F Fill Soap Dispenser ** ON A/C NOT FOR ALL
F Fill Soap Dispenser ** ON A/C NOT FOR ALL
   (1) Turn the cover (2) counterclockwise to release it from the shank (3) (refer to Step 1).
   (2) Carefully lift and remove the cover (2) together with the spout (1) and the tube (4) from the shank (3) (refer to Step 2).
   (3) Fill the soap dispenser with liquid soap through the shank (3) (refer to Step 3).
NOTE: For maximum performance of the liquid soap dispenser, use the liquid soap PN 83-182 - Supplier CWF Chemie Frankfurt GmbH.
If you use an equivalent liquid soap, it must have the viscosity of less than 30mPa.S.
   (4) Carefully put the cover (2) together with the spout (1) and the tube (4) on the shank (3).
   (5) Turn the cover (2) clockwise until it is locked in position on the shank (3).
Subtask 25-45-14-613-050-E ** ON A/C NOT FOR ALL
CAUTION: DO NOT USE INDUSTRIAL HAND CLEANERS, NATURAL SOAPS AND CLEANING AGENTS THAT CONTAIN ABRASIVES, SOLVENTS OR A LARGE PROPORTION OF DISINFECTANT. THESE MATERIALS CAN CAUSE THE PUMP MECHANISM TO WEAR MORE QUICKLY.
C. Servicing of the Soap Dispenser
NOTE: The dispenser is applicable for normal liquid hand-cleaning agents, soap creams and dish-washing agents for household use.
We recommend that you use mild, biodegradable, fully synthetic agents.
   (1) Fill the bottle of the soap dispenser.
F Soap Dispenser ** ON A/C NOT FOR ALL
     (a) Turn the pump-assembly (1) counter-clockwise with your fingers and remove it from the soap outlet (2).
     (b) Use a FUNNEL and fill the bottle with weak liquid soap.
     (c) Install the pump assembly (1) in the soap outlet (2) and tighten it clockwise with your fingers.
     (d) Operate the pump assembly (1) several times until soap comes out of the soap outlet (2).
     (e) Remove the unwanted soap with a lint-free cotton cloth Textile-Lint free Cotton - (Material No.14SBA1) .
     (f) Make sure that the work area is clean and clear of tools and other items.
Subtask 25-45-14-710-050-A
D. Do an Operational Test of the Soap Dispenser
   (1) Press the spout on the soap dispenser and make sure that the dispenser operates correctly.
5. Close-up
Subtask 25-45-14-862-050-A
A. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 06:22:14 UTC