W DOC AIRBUS | AMM A320F

Removal of the Static Inverter - Razor Supply


TASK 25-44-41-000-001-A
Removal of the Static Inverter - Razor Supply


ZONE: 200
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
261CC
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 25-23-42-000-002-A
Removal of the Ceiling Panels - Aft Utility Area
F Static Inverter - Razor Supply ** ON A/C NOT FOR ALL
F Mini Inverter - Razor Supply ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 25-44-41-861-050-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-44-41-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Remove the ceiling panel 261CC (Ref. AMM TASK 25-23-42-000-002).
Subtask 25-44-41-865-059-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
2000VULIGHT-LAV1LQJ01
** ON A/C NOT FOR ALL
2001VULAV SHAVER SOCKET1MTB01
Subtask 25-44-41-865-056-A
D. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
2000VULIGHT-LAV1LQJ01
4. Procedure
Subtask 25-44-41-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Static Inverter 2MT
F Static Inverter - Razor Supply ** ON A/C NOT FOR ALL
   (1) Disconnect the electrical connector (4)
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove the screws (2), the washers (1) and the static inverter (3).
Subtask 25-44-41-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Mini Inverter 10MT
F Mini Inverter - Razor Supply ** ON A/C NOT FOR ALL
   (1) Remove the screws (2) and the washers (3) and carefully lower the housing (1).
   (2) Unlock the spring latches (4) and disconnect the electrical connector (5)
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (4) Remove the screws (6), the washers (7) and the mini inverter (8).