Detailed Inspection of Lavatory Wall and Lower Attachment Points
TASK 25-40-00-220-001-A
Detailed Inspection of Lavatory Wall and Lower Attachment Points
Refer to the MPD TASK: 254000-03
DETAILED INSPECTION OF LAVATORY WALL AND LOWER ATTACHMENT POINTS.
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 25-40-00-861-055-A ** ON A/C NOT FOR ALL Subtask 25-40-00-861-055-B ** ON A/C NOT FOR ALL
Subtask 25-40-00-220-050-A ** ON A/C NOT FOR ALL
Subtask 25-40-00-862-056-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:34:58 UTC
Detailed Inspection of Lavatory Wall and Lower Attachment Points
ZONE: 200
1. Reason for the JobRefer to the MPD TASK: 254000-03
DETAILED INSPECTION OF LAVATORY WALL AND LOWER ATTACHMENT POINTS.
NOTE: REFER TO ISB 25-1365 FIGURE 1 SHEET 1 FLOW CHART FOR FURTHER DETAILS
2. Job Set-up InformationA. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 25-40-00-861-055-A ** ON A/C NOT FOR ALL Subtask 25-40-00-861-055-B ** ON A/C NOT FOR ALL
A. There is no special job set-up for this task.
4. ProcedureSubtask 25-40-00-220-050-A ** ON A/C NOT FOR ALL
A. Detailed Visual Inspection of the Lavatory Walls for Corrosion
(1) Do the detailed visual inspection of the affected areas as specified in ISB 25-1365.
Subtask 25-40-00-220-050-B ** ON A/C NOT FOR ALL (1) Do the detailed visual inspection of the affected areas as specified in ISB 25-1365.
A. General Information
(1) The detailed visual inspection of the lavatory walls for corrosion is not necessary because of the new honeycomb material introduced with modification 31574 K7442.
5. Close-up(1) The detailed visual inspection of the lavatory walls for corrosion is not necessary because of the new honeycomb material introduced with modification 31574 K7442.
Subtask 25-40-00-862-056-A ** ON A/C NOT FOR ALL