W DOC AIRBUS | AMM A320F

Removal of the Beverage Maker(s)


TASK 25-35-21-000-001-A
Removal of the Beverage Maker(s)


ZONE: 200
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
PLUG - BLANKING
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 38-10-00-614-002-A
Depressurization of the Potable Water System
3. Job Set-up
Subtask 25-35-21-861-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-35-21-860-051-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Depressurize the potable water system (Ref. AMM TASK 38-10-00-614-002).
   (2) On the water service panel, put the WARNING NOTICE(S) in position to tell persons not to pressurize the potable water system.
Subtask 25-35-21-860-052-A ** ON A/C NOT FOR ALL
C. At the applicable galley, on the galley control panel, open, safety and tag the circuit breaker(s) of the beverage maker(s).
4. Procedure
Subtask 25-35-21-020-050-C ** ON A/C NOT FOR ALL
A. Removal of the Beverage Maker
F Beverage Maker ** ON A/C NOT FOR ALL
WARNING: DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
WARNING: SUPPORT THE UNIT/ASSEMBLY. THE UNIT/ASSEMBLY IS HEAVY. IF YOU DO NOT SUPPORT IT, IT WILL FALL. THIS CAN CAUSE INJURY TO PERSONS, AND/OR DAMAGE TO EQUIPMENT.
   (1) Prevent damage to the component interfaces and the adjacent area.
   (2) Loosen the screw (4).
   (3) Set the lever (3) to the unlocked position.
   (4) Remove the beverage maker (2) from the galley as follows:
WARNING: MAKE SURE THAT THE POTABLE WATER SYSTEM IS DEPRESSURIZED. A PRESSURIZED SYSTEM CAN CAUSE INJURY TO PERSONS WHEN THEY DO WORK ON IT.
     (a) Carefully pull the beverage maker (2) out of the galley and disconnect the electrical connector, the water supply line and the drain line.
     (b) Remove the beverage maker (2) from the mounting rails (1).
   (5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (6) Put the PLUG-BLANKING in each disconnected line end.
[Rev.10 from 2021] 2026.04.01 06:13:35 UTC