W DOC AIRBUS | AMM A320F

Replacement of the Air Filter of the Air Chiller Unit


TASK 25-34-00-960-001-A
Replacement of the Air Filter of the Air Chiller Unit


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
1
AIR FILTER
AIPC 25-34-51-01-010
1
AIR FILTER
AIPC 25-34-51-02-010
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 25-34-00-861-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-34-00-941-050-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the overhead panel, on AIR COND panel 30VU:
     (a) Make sure that these pushbutton switches are released:
  • APU BLEED pushbutton switch (the ON legend is off)
  • All the ENG BLEED pushbutton switches (the OFF legends are on)
  • PACK 1 and PACK 2 pushbutton switches (the OFF legends are on).
     (b) Put the WARNING NOTICE(S) in position to tell persons not to operate these pushbutton switches.
   (2) On the HP and LP ground-air connectors:
     (a) Put the WARNING NOTICE(S) in position to tell persons not to connect the ground air supply.
Subtask 25-34-00-010-050-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) If you must replace the air filter of the air chiller unit of the Galley 1:
  • Remove the air grille from the air chiller compartment of the galley 1.
   (2) If you must replace the air filter of the air chiller unit of the Galley 2:
  • Remove the air grille from the air chiller compartment of the galley 2.
   (3) If you must replace the air filter of the air chiller unit of the Galley 5:
  • Remove the access panel of the air chiller unit.
4. Procedure
Subtask 25-34-00-960-050-E ** ON A/C NOT FOR ALL 5. Close-up
Subtask 25-34-00-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) If you replaced the air filter of the air chiller unit of the Galley 1:
  • Install the air grille on the air chiller compartment of the galley 1.
   (2) If you replaced the air filter of the air chiller unit of the Galley 2:
  • Install the air grille on the air chiller compartment of the galley 2.
   (3) If you replaced the air filter of the air chiller unit of the Galley 5:
  • Install the access panel of the air chiller unit .
   (4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Subtask 25-34-00-942-050-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) Remove the warning notice(s) from:
  • The HP and LP ground-air connectors
  • AIR COND panel 30VU.
Subtask 25-34-00-862-050-A ** ON A/C NOT FOR ALL
[Rev.9 from 2019] 2026.03.31 23:33:55 UTC