W DOC AIRBUS | AMM A320F

Installation of the Power Outlet Unit


TASK 25-18-11-400-801-A
Installation of the Power Outlet Unit


CAUTION: BEFORE YOU INSTALL/REMOVE THE GSE-TOOL, READ THE INSTRUCTIONS IN THE APPLICABLE GSE INSTRUCTION MANUAL. WHILE YOU OPERATE THIS TOOL, CAREFULLY OBEY THEM. IF YOU DO NOT OBEY THE INSTRUCTIONS, DAMAGE TO EQUIPMENT CAN OCCUR.
FIN: 4NA ** ON A/C NOT FOR ALL
FIN: 5NA ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
VOLTMETER - TRUE RMS AC VOLTAGE MEASURING
99D24003000001
1
PLUG-ELECTRICAL TEST
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 25-18-11-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-18-11-865-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUPILOTS OUTLETS/STAT INV1NAK25
121VUPILOTS OUTLETS/115V 60HZ2NAK23
4. Procedure
Subtask 25-18-11-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Power Outlet Unit
F Power Outlet Unit ** ON A/C NOT FOR ALL
   (1) Put the power outlet unit (2) in position on the VU panel (1).
   (2) Install the screws (3) and tighten them.
   (3) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (4) Make sure that all the electrical connections are clean and in the correct condition.
   (5) Connect the electrical connectors.
   (6) Put the VU panel (1) in position on the structure.
   (7) Install the washers (5) and the screws (4).
   (8) Tighten the screws (4).
Subtask 25-18-11-865-052-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUPILOTS OUTLETS/STAT INV1NAK25
121VUPILOTS OUTLETS/115V 60HZ2NAK23
Subtask 25-18-11-760-050-A ** ON A/C NOT FOR ALL
C. Test
NOTE: One of these two tools is necessary for this test: the 99D24003000001 PLUG-ELECTRICAL TEST or the VOLTMETER - TRUE RMS AC VOLTAGE MEASURING.
   (1) For the test with the 99D24003000001 PLUG-ELECTRICAL TEST:
     (a) On CAPT hand-microphone panel 17VU:
       1 Connect the 99D24003000001 PLUG-ELECTRICAL TEST to the CAPT outlet (5NA).
       2 On the 99D24003000001 PLUG-ELECTRICAL TEST, push the pushbutton switch. A light comes on.
       3 Connect the voltmeter to the 99D24003000001 PLUG-ELECTRICAL TEST and make sure that the voltage is 115VAC.
       4 Disconnect the voltmeter from the 99D24003000001 PLUG-ELECTRICAL TEST.
       5 Release the pushbutton switch. The light goes off.
       6 Disconnect the 99D24003000001 PLUG-ELECTRICAL TEST from the CAPT outlet (5NA).
     (b) On F/O hand-microphone panel 16VU:
       1 Connect the 99D24003000001 PLUG-ELECTRICAL TEST to the F/O outlet (4NA).
       2 On the 99D24003000001 PLUG-ELECTRICAL TEST, push the pushbutton switch. A light comes on.
       3 Connect the voltmeter to the 99D24003000001 PLUG-ELECTRICAL TEST and make sure that the voltage is 115VAC.
       4 Disconnect the voltmeter from the 99D24003000001 PLUG-ELECTRICAL TEST.
       5 Release the pushbutton switch. The light goes off.
       6 Disconnect the 99D24003000001 PLUG-ELECTRICAL TEST from the F/O outlet (4NA).
   (2) For the test with the VOLTMETER - TRUE RMS AC VOLTAGE MEASURING:
     (a) Do the next steps for the CAPT outlet:
       1 On panel 121VU, open circuit breaker PILOTS OUTLETS 2NA.
       2 On CAPT hand-microphone panel 17VU, connect the VOLTMETER - TRUE RMS AC VOLTAGE MEASURING to the CAPT outlet (5NA).
       3 On panel 121VU, close circuit breaker PILOTS OUTLETS 2NA.
       4 Make sure that the voltage is 115VAC.
       5 On panel 121VU, open circuit breaker PILOTS OUTLETS 2NA.
       6 Disconnect the VOLTMETER - TRUE RMS AC VOLTAGE MEASURING from the CAPT outlet (5NA).
       7 On panel 121VU, close circuit breaker PILOTS OUTLETS 2NA.
     (b) Do the next steps for the F/O outlet:
       1 On panel 121VU, open circuit breaker PILOTS OUTLETS 2NA.
       2 On F/O hand-microphone panel 16VU, connect the VOLTMETER - TRUE RMS AC VOLTAGE MEASURING to the F/O outlet (4NA).
       3 On panel 121VU, close circuit breaker PILOTS OUTLETS 2NA.
       4 Make sure that the voltage is 115VAC.
       5 On panel 121VU, open circuit breaker PILOTS OUTLETS 2NA.
       6 Disconnect the VOLTMETER - TRUE RMS AC VOLTAGE MEASURING from the F/O outlet (4NA).
       7 On panel 121VU, close circuit breaker PILOTS OUTLETS 2NA.
5. Close-up
Subtask 25-18-11-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Subtask 25-18-11-862-050-A ** ON A/C NOT FOR ALL
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).