W DOC AIRBUS | AMM A320F

Replacement of the Latch of Panel 212HW


TASK 25-13-41-960-801-A
Replacement of the Latch of Panel 212HW


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
212HW
 B. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
6
LATCH
AIPC 25-13-01-19-130
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 25-13-41-861-053-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-13-41-865-056-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM/AUDIO/ACP/F/O5RNG07
** ON A/C NOT FOR ALL
49VUCOM/AUDIO/FLT/INTPH9RNG08
49VUCOM/AUDIO/ACP/CAPT4RNG06
** ON A/C NOT FOR ALL
49VUCOM/ACP F/O/BITE/ INT 2 AUDIO/3&5 OCCPNT5RNG07
** ON A/C NOT FOR ALL
49VUCOM/INT/1+29RNG08
49VUCOM/ACP CAPT/SELCAL/INT 1 AUDIO/AVNCS4RNG06
** ON A/C NOT FOR ALL
121VUPILOTS OUTLETS/STAT INV1NAK25
121VUPILOTS OUTLETS/115V 60HZ2NAK23
4. Procedure
Subtask 25-13-41-020-060-A
A. Removal of Panel 212HW
   (1) Remove the screws (1) and the washers (2).
   (2) Loosen the fasteners (4).
   (3) Remove the panel (3).
Subtask 25-13-41-960-050-A
B. Replacement of the Latch of Panel 212HW
   (1) Remove the latch (6) from the door (5) and discard it.
   (2) Install the new AIPC 25-13-01-19-130 LATCH (6) on the door (5).
Subtask 25-13-41-420-060-A
C. Installation of Panel 212HW:
   (1) Put the panel (3) in position.
   (2) Install the washers (2) and the screws (1).
   (3) Tighten the screws (1).
   (4) Lock the fasteners (4).
5. Close-up
Subtask 25-13-41-410-052-A
A. Make sure that the work area is clean and clear of tools and other items.
Subtask 25-13-41-865-057-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM/AUDIO/ACP/F/O5RNG07
** ON A/C NOT FOR ALL
49VUCOM/AUDIO/FLT/INTPH9RNG08
49VUCOM/AUDIO/ACP/CAPT4RNG06
** ON A/C NOT FOR ALL
49VUCOM/ACP F/O/BITE/ INT 2 AUDIO/3&5 OCCPNT5RNG07
** ON A/C NOT FOR ALL
49VUCOM/INT/1+29RNG08
49VUCOM/ACP CAPT/SELCAL/INT 1 AUDIO/AVNCS4RNG06
** ON A/C NOT FOR ALL
121VUPILOTS OUTLETS/STAT INV1NAK25
121VUPILOTS OUTLETS/115V 60HZ2NAK23
Subtask 25-13-41-862-051-A
C. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.03.31 23:29:09 UTC