General Visual Inspection of EWIS of the 2000VU (EWIS)
TASK 24-92-00-210-029-A
General Visual Inspection of EWIS of the 2000VU (EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200223-02
GENERAL VISUAL INSPECTION OF EWIS OF THE 2000VU (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-92-00-010-093-A
Subtask 24-92-00-210-079-A
Subtask 24-92-00-410-091-A
[Rev.10 from 2021]
2026.03.31 23:26:10 UTC
General Visual Inspection of EWIS of the 2000VU (EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200223-02
GENERAL VISUAL INSPECTION OF EWIS OF THE 2000VU (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | FLASHLIGHT |
| No specific | AR | MIRROR - INSPECTION, FLEXIBLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 223 | FWD CAB OVERHEAD COMPARTMENT |
| 224 | FWD CAB OVERHEAD COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 52-10-00-010-001-A | Opening of the Passenger/Crew Door |
| TASK 52-10-00-410-001-A | Closing of the Passenger/Crew Door |
| ESPM 2052110 | |
Subtask 24-92-00-010-093-A
A. Get Access
(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at the zone 831 (841).
(2) Open the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-010-001).
(3) Open the circuit breaker panel 2000VU at the zone 220.
Subtask 24-92-00-862-081-A (1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at the zone 831 (841).
(2) Open the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-010-001).
(3) Open the circuit breaker panel 2000VU at the zone 220.
B. Make sure that the aircraft electrical circuits are de-energized
(Ref. AMM TASK 24-41-00-862-002).
4. Procedure(Ref. AMM TASK 24-41-00-862-002).
Subtask 24-92-00-210-079-A
A. General Visual Inspection of All Wiring of the 2000VU
(1) Do a visual inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation ESPM 2052110:
5. Close-up(1) Do a visual inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation ESPM 2052110:
NOTE: Use a FLASHLIGHT or a MIRROR - INSPECTION, FLEXIBLE if necessary.
(2) Make sure that there is no dust contamination. Subtask 24-92-00-410-091-A
A. Close Access
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Close the circuit breaker panel 2000VU at the zone 220.
(3) Close the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-410-001).
(4) Remove the access platform(s).
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Close the circuit breaker panel 2000VU at the zone 220.
(3) Close the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-410-001).
(4) Remove the access platform(s).
Forward Cabin Overhead Compartment - Inspection Area -Zones 223-224