W DOC AIRBUS | AMM A320F

Cleaning of EWIS Installed in the Bulk Cargo Compartment (Only If Contaminated)(EWIS)


TASK 24-92-00-100-030-A
Cleaning of EWIS Installed in the Bulk Cargo Compartment (Only If Contaminated)(EWIS)


ZONE: 161
ZONE: 162
1. Reason for the Job
Refer to the MPD TASK: 200161-01
CLEANING OF EWIS INSTALLED IN THE BULK CARGO COMPARTMENT (ONLY IF CONTAMINATED) (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
161
BULK CARGO COMPARTMENT
162
BULK CARGO COMPARTMENT
826
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 25-55-12-000-003-A
Removal of the Sidewall Panels in the Aft Cargo Compartment - FR59/FR65
TASK 25-55-12-400-003-A
Installation of the Sidewall Panels in the Aft Cargo Compartment - FR59/FR65
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-003-A
Open the FWD or Aft Cargo-Compartment Door with the Hand Pump
TASK 52-30-00-860-004-A
Close the FWD or Aft Cargo-Compartment Door with the Hand Pump
ESPM 2055000
3. Job Set-up
Subtask 24-92-00-010-149-B
A. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
   (2) Open the aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001) and (Ref. AMM TASK 52-30-00-860-003).
   (3) Remove the sidewall panels in the aft cargo compartment from FR59 to FR65 (Ref. AMM TASK 25-55-12-000-003).
   (4) If installed, remove the additional center tank No. 5 from zones 161 and 162, (Ref. AMM D/O 28-11-27-00) if applicable.
Subtask 24-92-00-862-136-A
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
4. Procedure
Subtask 24-92-00-160-078-A
A. Cleaning of All Wiring Installed in the Bulk Cargo Compartment (Only Contaminated Wiring)
   (1) Clean the wiring if there is dust, lint or hydraulic contamination ESPM 2055000.
     (a) On the AC/DC power-distribution routes: 1P and 2P.
     (b) On the flight control routes: 7S and 8S.
     (c) On the engine control routes: 1S, 2S and APU.
     (d) On the other routes: 1M and 2M.
     (e) On the coaxial wiring routes: 5T and 6T.
5. Close-up
Subtask 24-92-00-410-147-B
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
if applicable.
   (2) If removed, install the additional center tank No. 5 in zones 161 and 162, (Ref. AMM D/O 28-11-27-40)
   (3) Install the sidewall panels in the aft cargo compartment from FR59 to FR65 (Ref. AMM TASK 25-55-12-400-003).
   (4) Close the aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-002) and (Ref. AMM TASK 52-30-00-860-004).
   (5) Remove the access platform(s).
[Rev.10 from 2021] 2026.03.31 23:27:28 UTC