Removal of the Contactor Located in the Panel 200VU


TASK 24-56-55-000-002-A
Removal of the Contactor Located in the Panel 200VU


WARNING: MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT ELECTRICAL CIRCUITS. THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS CONNECTED.
FIN: 13MC ** ON A/C NOT FOR ALL
FIN: 15MC
FIN: 17MC
FIN: 4MC ** ON A/C NOT FOR ALL
FIN: 5MC
FIN: 6MC
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 25-23-41-000-001-A
Removal of the Ceiling Panels
TASK 25-23-42-000-001-A
Removal of the Ceiling Panels - Forward Utility Area
3. Job Set-up
Subtask 24-56-55-860-052-B
A. Safety Precautions
   (1) On the overhead panel, on the ELEC section of panel 35VU:
     (a) Make sure that the GALY & CAB pushbutton switch is released (the OFF legend is on).
     (b) Put the WARNING NOTICE(S) in position to tell persons not to operate the GALY & CAB pushbutton switch.
Subtask 24-56-55-010-051-A
B. Removal of the Ceiling Panels
   (1) Remove the ceiling panels (Ref. AMM TASK 25-23-41-000-001).
   (2) Remove the forward utility-area ceiling-panels (Ref. AMM TASK 25-23-42-000-001).
Subtask 24-56-55-865-053-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUELEC/GALLEY/CNTOR7MCS28
122VUELEC/GALY & CAB/CTL1XAS26
** ON A/C NOT FOR ALL
123VUAFT GALLEY/FEEDER A3MCAF04
** ON A/C ALL
123VUFWD GALLEY/FEEDER F16MCAC10
123VUAFT GALLEY/FEEDER E14MCAF09
** ON A/C NOT FOR ALL
123VUAFT GALLEY/FEEDER B12MCAD09
123VUFWD GALLEY/FEEDER D2MCAD04
123VUFWD GALLEY/FEEDER C1MCAE10
** ON A/C NOT FOR ALL
123VUFWD GALLEY/FEEDER D2MCAE02
4. Procedure
Subtask 24-56-55-020-051-A
A. Removal of the Contactor
CAUTION: REMOVE THE CONTACTOR ONLY AND NOT THE BASE OR THE MODULE WHERE THE WIRES ARE CONNECTED.
   (1) Disconnect the electrical connector (4) from the contactor (3).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Loosen the captive screws (5). Do not remove the captive screws (5) and the spring washers (6) from the contactor (3).
   (4) Remove the contactor (3).