W DOC AIRBUS | AMM A320F

Removal of the Anti-Hijack-System Cameras


TASK 23-72-51-000-001-A
Removal of the Anti-Hijack-System Cameras


ZONE: 210
ZONE: 220
FIN: 12RA ** ON A/C NOT FOR ALL
FIN: 13RA ** ON A/C NOT FOR ALL
FIN: 14RA ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
220
FWD CAB UTILITY AREAS
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 25-23-42-000-001-A
Removal of the Ceiling Panels - Forward Utility Area
3. Job Set-up
Subtask 23-72-51-861-050-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 23-72-51-865-054-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUDOORS/CKPT/VIDEO/SPLY15RAT16
4. Procedure
Subtask 23-72-51-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Cameras
F Cameras ** ON A/C NOT FOR ALL
NOTE: The removal procedure for all the cameras is the same. Only one procedure is given.
   (1) Remove the caps (4).
   (2) Hold the camera (3) in position.
   (3) Remove the screws (5) and the washers (6).
   (4) Carefully remove the camera (3) with the adapter plate (2) until you can disconnect the electrical connector (1).
   (5) Disconnect the electrical connector (1) and remove the camera (3) with the adapter plate (2).
NOTE: Keep the adapter plate (2) with the camera (3) for the installation procedure.
   (6) If you cannot get access to disconnect the electrical connector (1), do the subsequent steps:
     (a) Loosely attach the camera (3) to the ceiling panel with the screws (5).
     (b) Remove the ceiling panel and move it until you can get access to the electrical connector (1) (Ref. AMM TASK 25-23-42-000-001).
     (c) Disconnect the electrical connector (1) from the camera (3).
     (d) Remove the three screws (5) and remove the camera (3) with the adapter plate (2) from the ceiling panel.
   (7) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.