Discard Filter Cartridge (PALL)


TASK 21-26-43-920-001-A
Discard Filter Cartridge (PALL)


WARNING: PUT ON GLOVES, A COVERALL WITH A HOOD, GOGGLES AND A PARTICULATE RESPIRATOR BEFORE YOU TOUCH THE FILTER. THE FILTER REMOVES SMALL PARTICLES (SMOKE, DUST, LINT, FIBERS, POLLEN) AND INFECTIOUS MATERIALS (BACTERIA, VIRUSES, MOLD SPORES, FUNGI) FROM THE AIR. THESE MATERIALS CAN CAUSE ILLNESS.
WARNING: DO NOT LET THE FILTER TOUCH YOUR SKIN. DO NOT SHAKE OR HIT THE FILTER. DO NOT LET THE FILTER FALL. DO NOT USE COMPRESSED AIR TO CLEAN THE FILTER OR FILTER HOUSING. THIS CAN CAUSE THE INFECTIOUS MATERIAL TO BECOME AIRBORNE. DISCARD THE FILTER IN A PLASTIC DISPOSAL BAG. IF YOU DO NOT OBEY THESE INSTRUCTIONS, INFECTIOUS MATERIAL FROM THE FILTER CAN CAUSE ILLNESS.
WARNING: PUT ALL AIR FILTERS THAT YOU REMOVE FROM THE AIRCRAFT INTO PLASTIC DISPOSAL BAGS. AIR FILTERS CAN CONTAIN INFECTIOUS MATERIALS WHICH CAN CAUSE ILLNESS. OBEY AIRLINE POLICY AND LOCAL HEALTH DEPARTMENT AND LAW ENFORCEMENT REGULATIONS FOR DISPOSAL OF INFECTIOUS MATERIALS.
ZONE: 120
1. Reason for the Job
Refer to the MPD TASK: 212643-07
DISCARD FILTER CARTRIDGE (PALL)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
824
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
3
FILTER CARTRIDGE
AIPC 21-26-43-01-020
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
CAUTION: USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE DAMAGE TO ELECTRICAL EQUIPMENT.
Subtask 21-26-43-861-091-A ** ON A/C NOT FOR ALL
A. Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
Subtask 21-26-43-865-093-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/AVNCS VENT/CTL6HQD06
49VUAIR COND/AVNCS VENT/CTL5HQD05
122VUAIR COND/AVNCS/VENT/MONG3HQY17
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAE02
** ON A/C NOT FOR ALL
123VUAVNCS VENT/BLOWER/FAN1HQAD10
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAC04
Subtask 21-26-43-010-080-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the access door 824.
   (2) Open the access door 824.
4. Procedure
Subtask 21-26-43-020-068-A ** ON A/C NOT FOR ALL
A. Removal of the Filter Cartridge
   (1) Release the two fasteners (5).
     (a) Move the locks (4) along the fasteners (5).
     (b) Lift the fasteners (5) to release the door of the filter housing (1).
   (2) Open the door of the filter housing (1).
   (3) Pull up the strap to release the spring (2) from the locking block.
   (4) Lower the spring (2) and disengage the filter cartridge (3) from the filter housing (1).
   (5) Discard the filter cartridge (3).
Subtask 21-26-43-420-066-A ** ON A/C NOT FOR ALL 5. Close-up
Subtask 21-26-43-410-077-A ** ON A/C NOT FOR ALL
Subtask 21-26-43-865-094-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/AVNCS VENT/CTL6HQD06
49VUAIR COND/AVNCS VENT/CTL5HQD05
122VUAIR COND/AVNCS/VENT/MONG3HQY17
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAE02
** ON A/C NOT FOR ALL
123VUAVNCS VENT/BLOWER/FAN1HQAD10
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAC04
Subtask 21-26-43-862-090-A ** ON A/C NOT FOR ALL
C. De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001).