W DOC AIRBUS | AMM A320F

Replenish Oil System


TASK 12-13-80-610-002-B
Replenish Oil System


ZONE: 436
ZONE: 446
1. Reason for the Job
Refer to the MPD TASK: 801110-C2
REPLENISH OIL SYSTEM
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.CP2442)
engine oil
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
436
FAN AND ACCESSORY GEARBOX
446
FAN AND ACCESSORY GEARBOX
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
20
O-RING
AIPC 80-11-10-01-130
30
O-RING
AIPC 80-11-10-01-130
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 80-11-10-000-002-A
Removal of the Pneumatic Starter
TASK 80-11-10-400-002-A
Installation of the Pneumatic Starter
3. Job Set-up
Subtask 12-13-80-941-053-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 12-13-80-010-053-A ** ON A/C NOT FOR ALL
B. Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure
Subtask 12-13-80-010-054-A ** ON A/C NOT FOR ALL
A. Remove the filler plug:
   (1) Remove the filler plug (10), and overflow plug (40). Push inward and simultaneously turn counter clockwise to disengage locking device. Discard O-rings (20 and 30).
Subtask 12-13-80-610-050-A ** ON A/C NOT FOR ALL
B. Fill the starter housing
CAUTION: BE CAREFUL NOT TO OVERFILL THE STARTER. IF YOU PUT TOO MUCH OIL IN THE STARTER, DAMAGE TO THE ENGINE CAN OCCUR.
   (1) Fill the starter housing with engine oil (Material No.CP2442) through the filler port until the oil flows from the overflow port.
NOTE: The added quantity of oil should be less than 0.32 quart (approximately 0.3 liter). If the quantity is more than 0.32 quart, replace the starter (Ref. AMM TASK 80-11-10-000-002) and (Ref. AMM TASK 80-11-10-400-002)
Subtask 12-13-80-410-053-A ** ON A/C NOT FOR ALL 5. Close-up
Subtask 12-13-80-410-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021] 2026.03.31 22:55:46 UTC