General Visual Inspection of FWD and AFT Emergency Exits including Door Stops on Fuselage Door Frames (EWIS)
TASK 05-28-30-200-011-A
General Visual Inspection of FWD and AFT Emergency Exits including Door Stops on Fuselage Door Frames (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-833-04
GENERAL VISUAL INSPECTION OF FWD AND AFT EMERGENCY EXITS INCLUDING DOOR STOPS ON FUSELAGE DOOR FRAMES (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-28-30-010-056-A ** ON A/C NOT FOR ALL
Subtask 05-28-30-210-060-A ** ON A/C NOT FOR ALL
Subtask 05-28-30-410-056-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 22:51:01 UTC
General Visual Inspection of FWD and AFT Emergency Exits including Door Stops on Fuselage Door Frames (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-833-04
GENERAL VISUAL INSPECTION OF FWD AND AFT EMERGENCY EXITS INCLUDING DOOR STOPS ON FUSELAGE DOOR FRAMES (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 833 | EMERGENCY EXITS |
| 834 | EMERGENCY EXITS |
| 843 | EMERGENCY EXITS |
| 844 | EMERGENCY EXITS |
| 833, 834, 843, 844 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-22-00-010-002-A | Opening of the Emergency Exit Doors from the Outside |
| TASK 52-22-00-410-002-A | Closing of the Emergency Exit Doors from the Outside |
Subtask 05-28-30-010-056-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zones 833 ( 843) and 834 ( 844).
(2) Open emergency exit doors 833 ( 843) and 834 ( 844) (Ref. AMM TASK 52-22-00-010-002).
4. Procedure(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zones 833 ( 843) and 834 ( 844).
(2) Open emergency exit doors 833 ( 843) and 834 ( 844) (Ref. AMM TASK 52-22-00-010-002).
Subtask 05-28-30-210-060-A ** ON A/C NOT FOR ALL
A. Inspection
Forward and Aft Emergency Exits which include the Door Stops on the Fuselage Door Frames ** ON A/C NOT FOR ALL
(1) Do a general visual inspection of the forward and aft emergency exits. This inspection includes the door stops on the fuselage door frames.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations are attached correctly.
5. Close-up
Forward and Aft Emergency Exits which include the Door Stops on the Fuselage Door Frames ** ON A/C NOT FOR ALL (2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations are attached correctly.
Subtask 05-28-30-410-056-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Close emergency exit doors 833 ( 843) and 834 ( 844) (Ref. AMM TASK 52-22-00-410-002).
(2) Remove the access platform(s).
(1) Close emergency exit doors 833 ( 843) and 834 ( 844) (Ref. AMM TASK 52-22-00-410-002).
(2) Remove the access platform(s).