General Visual Inspection of FWD and Aft Overwing Emergency Exits including Door Surround on Fuselage and Door Seals, External Surface (EWIS)
TASK 05-28-30-200-007-A
General Visual Inspection of FWD and Aft Overwing Emergency Exits including Door Surround on Fuselage and Door Seals, External Surface (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-833-02
GENERAL VISUAL INSPECTION OF FWD AND AFT OVERWING EMERGENCY EXITS INCLUDING DOOR SURROUND ON FUSELAGE AND DOOR SEALS, EXTERNAL SURFACE (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-28-30-010-054-A ** ON A/C NOT FOR ALL
Subtask 05-28-30-210-076-A ** ON A/C NOT FOR ALL
Subtask 05-28-30-410-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 22:51:01 UTC
General Visual Inspection of FWD and Aft Overwing Emergency Exits including Door Surround on Fuselage and Door Seals, External Surface (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-833-02
GENERAL VISUAL INSPECTION OF FWD AND AFT OVERWING EMERGENCY EXITS INCLUDING DOOR SURROUND ON FUSELAGE AND DOOR SEALS, EXTERNAL SURFACE (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 833 | EMERGENCY EXITS |
| 834 | EMERGENCY EXITS |
| 843 | EMERGENCY EXITS |
| 844 | EMERGENCY EXITS |
| 831, 832, 833, 833AZ, 833BZ, 834, 834AZ, 834BZ, 841, 842, 843, 843AZ, 843BZ, 844, 844AZ, 844BZ |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-23-47-000-001-A | Removal of the Lining from the Emergency Exit Hatches |
| TASK 25-23-47-400-001-A | Installation of the Lining on the Emergency Exit Hatches |
| TASK 52-10-00-010-001-A | Opening of the Passenger/Crew Door |
| TASK 52-10-00-410-001-A | Closing of the Passenger/Crew Door |
| TASK 52-21-11-000-001-A | Removal of the Emergency Exit Hatch |
| TASK 52-21-11-400-001-A | Installation of the Emergency Exit Hatch |
Subtask 05-28-30-010-054-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at zone 831 ( 841) or 832 ( 842).
(2) Open passenger/crew door 831 ( 841) or 832 ( 842) (Ref. AMM TASK 52-10-00-010-001).
(3) Open emergency exit doors 833 ( 843) and 834 ( 844) (Ref. AMM TASK 52-21-11-000-001).
(4) Remove emergency-exit door panels 833AZ ( 843AZ), 833BZ ( 843BZ), 834AZ ( 844AZ) and 834BZ ( 844BZ) (Ref. AMM TASK 25-23-47-000-001).
(5) Lift the insulation blanket.
4. Procedure(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at zone 831 ( 841) or 832 ( 842).
(2) Open passenger/crew door 831 ( 841) or 832 ( 842) (Ref. AMM TASK 52-10-00-010-001).
(3) Open emergency exit doors 833 ( 843) and 834 ( 844) (Ref. AMM TASK 52-21-11-000-001).
(4) Remove emergency-exit door panels 833AZ ( 843AZ), 833BZ ( 843BZ), 834AZ ( 844AZ) and 834BZ ( 844BZ) (Ref. AMM TASK 25-23-47-000-001).
(5) Lift the insulation blanket.
Subtask 05-28-30-210-076-A ** ON A/C NOT FOR ALL
A. Inspection
Forward and Aft Overwing Emergency Exits which include Door Surround on Fuselage, the Door Seals and the External Surface ** ON A/C NOT FOR ALL
(1) Do a general visual inspection of the forward and aft overwing emergency-exits (zones 833 (843) and 834 (844)). This inspection includes the door surround on fuselage, the door seals and the external surface of the doors.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations are correctly attached.
5. Close-up
Forward and Aft Overwing Emergency Exits which include Door Surround on Fuselage, the Door Seals and the External Surface ** ON A/C NOT FOR ALL (2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations are correctly attached.
Subtask 05-28-30-410-054-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Put the insulation blanket back in position.
(3) Install emergency-exit door panels 833AZ ( 843AZ), 833BZ ( 843BZ), 834AZ ( 844AZ) and 834BZ ( 844BZ) (Ref. AMM TASK 25-23-47-400-001).
(4) Close emergency exit doors 833 ( 843) and 834 ( 844) (Ref. AMM TASK 52-21-11-400-001).
(5) Close passenger/crew door 831 ( 841) or 832 ( 842) (Ref. AMM TASK 52-10-00-410-001).
(6) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Put the insulation blanket back in position.
(3) Install emergency-exit door panels 833AZ ( 843AZ), 833BZ ( 843BZ), 834AZ ( 844AZ) and 834BZ ( 844BZ) (Ref. AMM TASK 25-23-47-400-001).
(4) Close emergency exit doors 833 ( 843) and 834 ( 844) (Ref. AMM TASK 52-21-11-400-001).
(5) Close passenger/crew door 831 ( 841) or 832 ( 842) (Ref. AMM TASK 52-10-00-410-001).
(6) Remove the access platform(s).