Removal of the Lining from the Emergency Exit Hatches
TASK 25-23-47-000-001-A
Removal of the Lining from the Emergency Exit Hatches
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 25-23-47-861-070-A ** ON A/C NOT FOR ALL Subtask 25-23-47-010-051-A ** ON A/C NOT FOR ALL 4. Procedure
Subtask 25-23-47-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:54:59 UTC
Removal of the Lining from the Emergency Exit Hatches
NOTE: The removal and installation of the linings is the same for all the emergency exit hatches.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 52-21-11-000-001-A | Removal of the Emergency Exit Hatch |
Subtask 25-23-47-861-070-A ** ON A/C NOT FOR ALL Subtask 25-23-47-010-051-A ** ON A/C NOT FOR ALL 4. Procedure
Subtask 25-23-47-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Lining
Lining - Emergency Exit Hatch ** ON A/C NOT FOR ALL
Lining - Emergency Exit Hatch ** ON A/C NOT FOR ALL
(1) Remove the screws (3), (5) and the washers (4), (6) that attach the lining (2) to the emergency exit hatch (1) and remove it.
Lining - Emergency Exit Hatch ** ON A/C NOT FOR ALL
Lining - Emergency Exit Hatch ** ON A/C NOT FOR ALL