General Visual Inspection of Dry Bay (Outboard) (EWIS)
TASK 05-25-60-200-001-A
General Visual Inspection of Dry Bay (Outboard) (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-560-01
GENERAL VISUAL INSPECTION OF DRY BAY (OUTBOARD) (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-25-60-010-050-A
Subtask 05-25-60-210-050-A
Subtask 05-25-60-410-050-A
[Rev.10 from 2021]
2026.03.31 22:50:27 UTC
General Visual Inspection of Dry Bay (Outboard) (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-560-01
GENERAL VISUAL INSPECTION OF DRY BAY (OUTBOARD) (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT) |
| No specific | 1 | FLASHLIGHT |
| No specific | 1 | MIRROR - INSPECTION |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 560 | DRY BAY (OUTBOARD) |
| 660 | DRY BAY (OUTBOARD) |
| 560AB, 660AB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 57-27-11-000-002-A | Removal of the Access Panel |
| TASK 57-27-11-400-002-A | Installation of the Access Panel |
Subtask 05-25-60-010-050-A
A. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position at zones 560 and 660.
(3) Remove access panels 560AB and 660AB (Ref. AMM TASK 57-27-11-000-002).
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT) in position at zones 560 and 660.
WARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
(2) Put on and attach a safety harness before you start work in the work area.(3) Remove access panels 560AB and 660AB (Ref. AMM TASK 57-27-11-000-002).
Subtask 05-25-60-210-050-A
A. Inspection
(1) If necessary, use the FLASHLIGHT and the MIRROR - INSPECTION to do this inspection.
(2) Do a general visual inspection of the dry bay (outboard) (zones 560 and 660).
(3) Make sure that:
5. Close-up(1) If necessary, use the FLASHLIGHT and the MIRROR - INSPECTION to do this inspection.
(2) Do a general visual inspection of the dry bay (outboard) (zones 560 and 660).
(3) Make sure that:
- There is no damage (corrosion, leaks or cracks) on all the parts of the components and the structure that you can see.
- All the installations (wiring, ducting and piping) are correctly attached.
Subtask 05-25-60-410-050-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access panels 560AB and 660AB (Ref. AMM TASK 57-27-11-400-002).
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access panels 560AB and 660AB (Ref. AMM TASK 57-27-11-400-002).
(3) Remove the access platform(s).
Dry Bay (Outboard)