W DOC AIRBUS | AMM A320F

GENERAL VISUAL INSPECTION OF AIR INTAKE (EWIS) (INTERNAL AREA AS FAR AS VISIBLE)


TASK 05-24-30-210-801-A
GENERAL VISUAL INSPECTION OF AIR INTAKE (EWIS) (INTERNAL AREA AS FAR AS VISIBLE)


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
ZONE: 433
ZONE: 434
ZONE: 443
ZONE: 444
1. Reason for the Job
Refer to the MPD TASK: ZL-433-02
GENERAL VISUAL INSPECTION OF AIR INTAKE (EWIS) (INTERNAL AREA AS FAR AS VISIBLE)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
433
AIR INTAKE LIP
434
AIR INTAKE LIP
443
AIR INTAKE LIP
444
AIR INTAKE LIP
434AZ, 437AL, 438AR, 444AZ, 447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-802-A
Closing of the Fan Cowl Doors
TASK 71-61-11-000-801-A
Removal of the Aft Bulkhead T2 Panel
TASK 71-61-11-400-801-A
Installation of the Aft Bulkhead T2 Panel
3. Job Set-up
Subtask 05-24-30-010-053-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) in position at zone 433 (443).
   (2) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
437AL 438AR 447AL and 448AR.
   (3) Remove the access panels (Ref. AMM TASK 71-61-11-000-801):
434AZ and 444AZ.
4. Procedure
Subtask 05-24-30-210-053-A ** ON A/C NOT FOR ALL
A. Do a general visual inspection of the air intake (internal area as far as visible).
Make sure that:
  • There is no damage (corrosion, leaks or cracks) on all the parts of the components and the structure that you can see
  • All the installations (wiring, piping, ducting) are correctly attached.
5. Close-up
Subtask 05-24-30-410-053-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panels (Ref. AMM TASK 71-61-11-400-801):
434AZ and 444AZ.
   (3) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
437AL 438AR 447AL and 448AR.
   (4) Remove the access platform(s).
[Rev.10 from 2021] 2026.03.31 22:49:55 UTC