GENERAL VISUAL INSPECTION OF TRIMMABLE HORIZONTAL STABILIZER TIP (EWIS)
TASK 05-23-30-200-002-A
GENERAL VISUAL INSPECTION OF TRIMMABLE HORIZONTAL STABILIZER TIP (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-332-01
GENERAL VISUAL INSPECTION OF TRIMMABLE HORIZONTAL STABILIZER TIP (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-23-30-010-051-A
Subtask 05-23-30-210-051-A
Subtask 05-23-30-410-051-A
[Rev.10 from 2021]
2026.03.31 22:49:42 UTC
GENERAL VISUAL INSPECTION OF TRIMMABLE HORIZONTAL STABILIZER TIP (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-332-01
GENERAL VISUAL INSPECTION OF TRIMMABLE HORIZONTAL STABILIZER TIP (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 332 | THS TIP |
| 342 | THS TIP |
| 332AB, 342AB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 55-14-11-000-001-A | Removal of Trimmable Horizontal Stabilizer (THS) Tips 332AB/342AB |
| TASK 55-14-11-400-001-A | Installation of Trimmable Horizontal Stabilizer (THS) Tips 332AB/342AB |
Subtask 05-23-30-010-051-A
A. Get Access
(1) Put an ACCESS PLATFORM 4M (13 FT) in position.
(2) Remove the tip 332AB / 342AB (Ref. AMM TASK 55-14-11-000-001).
4. Procedure(1) Put an ACCESS PLATFORM 4M (13 FT) in position.
(2) Remove the tip 332AB / 342AB (Ref. AMM TASK 55-14-11-000-001).
Subtask 05-23-30-210-051-A
A. Inspection
(1) Do a general visual inspection of the tip of the trimmable horizontal stabilizer.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting, piping) are attached correctly.
5. Close-up(1) Do a general visual inspection of the tip of the trimmable horizontal stabilizer.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting, piping) are attached correctly.
Subtask 05-23-30-410-051-A
A. Close Access
(1) Install the tip 332AB / 342AB. (Ref. AMM TASK 55-14-11-400-001)
(2) Remove the access platform(s).
(1) Install the tip 332AB / 342AB. (Ref. AMM TASK 55-14-11-400-001)