Zonal Inspection as far as Visible from the Ground of the Nose Gear Well (Zones 123)
TASK 05-21-20-200-002-A
Zonal Inspection as far as Visible from the Ground of the Nose Gear Well (Zones 123)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 05-21-20-010-051-A 4. Procedure
Subtask 05-21-20-210-051-A
Subtask 05-21-20-410-051-A
[Rev.10 from 2021]
2026.03.31 22:48:29 UTC
Zonal Inspection as far as Visible from the Ground of the Nose Gear Well (Zones 123)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 123 | NOSE GEAR WELL |
| 124 | NOSE GEAR WELL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 32-22-00-010-001-A | Nose Gear Doors - Ground Doors Opening |
| TASK 32-22-00-410-001-A | Nose Gear Doors - Ground Doors Closing |
Subtask 05-21-20-010-051-A 4. Procedure
Subtask 05-21-20-210-051-A
A. Inspection
(1) Do a general visual inspection of the nose gear well (Zones 123 and 124).
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting, piping) are attached correctly.
5. Close-up(1) Do a general visual inspection of the nose gear well (Zones 123 and 124).
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting, piping) are attached correctly.
Subtask 05-21-20-410-051-A