W DOC AIRBUS | TSM A320F

LPC (2.5) Bleed Valve Actuator Positon Error - Track Check on Channel A and B


TASK 75-32-00-810-866-A
LPC (2.5) Bleed Valve Actuator Positon Error - Track Check on Channel A and B


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 75-32-00-810-846-A
LPC (2.5) Bleed Valve Actuator Position Error - Trach Check Channel A
TSM TASK 75-32-00-810-847-A
LPC (2.5) Bleed Valve Actuator Position Error - Trach Check Channel B
3. Fault Confirmation
Subtask 75-32-00-710-121-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 75-32-00-810-147-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 75-32-00-810-846).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 75-32-00-810-847).
5. Close-up
Subtask 75-32-00-860-084-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:37:23 UTC