W DOC AIRBUS | TSM A320F

HPC SVA Master/Slave Actuator Position Error - Track Check Channel B


TASK 75-31-00-810-822-A
HPC SVA Master/Slave Actuator Position Error - Track Check Channel B


1. Possible Causes
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
MULTIMETER - STANDARD
No specific
1
PLIERS - JAWED, SOFT
 B. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 71-00-00-810-834-A
General Troubleshooting Guidelines for Additional Troubleshooting Information
TSM TASK 71-00-00-810-835-A
Component and Harness Intermittent Troubleshooting Procedure for Guidance Troubleshooting Intermittent Faults
AMM 70-70-00-910-803
SPOP 6 - Cleaning of the Contact Points and Wiring Harnesses
AMM 73-21-00-710-809
Test No.15 - Operation Test (Dry Motor) of the FADEC System Engine Actuators
AMM 73-21-01-000-801
Removal of the Electronic Engine Control (EEC)
AMM 73-21-01-400-801
Installation of the Electronic Engine Control (EEC)
AMM 73-21-63-000-802
Removal of the Electronic Engine Control (EEC) Wiring Harness (W03)
AMM 73-21-63-400-802
Installation of the Electronic Engine Control (EEC) Wiring Harness (W03)
AMM 73-21-64-000-802
Removal of the Electronic Engine Control (EEC) Wiring Harness (W04)
AMM 73-21-64-400-802
Installation of the Electronic Engine Control (EEC) Wiring Harness (W04)
AMM 73-21-68-000-802
Removal of the EEC Wiring Harness (WC08)
AMM 73-21-68-400-802
Installation of the EEC Wiring Harness (WC08)
AMM 75-31-00-200-802
Mechanical Check of the High Pressure Compressor (HPC) Stator Vane Control System
AMM 75-31-02-000-801
Removal of the High Pressure Compressor (HPC) Stator Vane Actuator (SVA) Primary
AMM 75-31-02-400-801
Installation of the High Pressure Compressor (HPC) Stator Vane Actuator (SVA) Primary
AMM 78-36-00-010-802
Opening of the Thrust Reverser Cowl-Doors
AMM 78-36-00-410-802
Closing of the Thrust Reverser Cowl-Doors
3. Fault Confirmation
Subtask 75-31-00-710-067-A ** ON A/C NOT FOR ALL
A. Do the FADEC system actuator test to confirm this fault AMM 73-21-00-710-809.
NOTE: The Electronic Engine Control (EEC) has detected that the High Pressure Compressor (HPC) Stator Vane Actuator (SVA) primary is not able to move to its commanded position within an acceptable period of time in channel B. The HPC SVA primary is mounted on HPC bellcrank mount bracket, located at the 3 o'clock position.
NOTE: Position faults from fuel driven actuators may appear after servicing the engine fuel filter or other fuel system parts due to entrapped air in the system. Performing the FADEC system actuator test again will purge the air. If the actuator position faults do not clear after one or two actuator tests proceed to troubleshoot the system.
   (1) If the maintenance message does not come back, do a mechanical test and inspection of the HPC stator vane control system AMM 75-31-00-200-802.
     (a) If the HPC SVA primary (4052KS), linkages, or unison rings are binding, repair them or remove the engine from service.
       1 If no problems are found, examine the harness and electrical connectors for problems as described in the component and harness intermittent troubleshooting procedure (Ref. TSM TASK 71-00-00-810-835).
       2 If no problems are found, return the engine to service. Monitor the engine for reoccurring maintenance message.
         a If the fault returns, replace PRIMARY ACTUATOR-HPC STATOR VANE [4052KS] AMM 75-31-02-000-801 and AMM 75-31-02-400-801.
   (2) If the maintenance message comes back (hard fault), go to the Para. Fault Isolation.
4. Fault Isolation
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS WARNING, INJURY CAN OCCUR.
WARNING: REFER TO THE MSDS FOR ALL MATERIAL USED AND THE MANUFACTURER'S SAFETY INSTRUCTIONS FOR ALL EQUIPMENT USED. IF YOU DO NOT OBEY THIS WARNING, INJURY CAN OCCUR.
CAUTION: MAKE SURE YOU REMOVE ELECTRICAL POWER FROM THE EEC BEFORE YOU REMOVE THE ELECTRICAL CONNECTORS. IF YOU DO NOT OBEY THIS INSTRUCTION, DAMAGE TO THE EEC CAN OCCUR.
Subtask 75-31-00-810-070-A ** ON A/C NOT FOR ALL
A. If there is confirmation of the fault:
   (1) Open the thrust reverser cowl-doors AMM 78-36-00-010-802.
   (2) Do a mechanical test and inspection of HPC SVA system AMM 75-31-00-200-802.
     (a) Repair any problems that you find.
     (b) Do the test given in Para. 3.
   (3) If no faults are found or the problem continues:
     (a) Replace PRIMARY ACTUATOR-HPC STATOR VANE [4052KS] AMM 75-31-02-000-801 and AMM 75-31-02-400-801.
     (b) Do the test given in Para. 3.
   (4) If the fault continues:
     (a) Examine the W04 (4088KS), WC08 (4094KS) and W03 (4087KS) harnesses, connectors P5 (4000KS-P5) and P6 (4000KS-P6) - EEC (4000KS), interconnect J108 (4111VC)/P108 (4111VC-A) and connectors P25 (4052KS-P25) and P24 (4052KS-P24) - HPC SVA primary (4052KS), for problems which are possible between the EEC (4000KS) and the HPC SVA primary (4052KS).
     (b) Inspect for harness damage.
     (c) Inspect for loose or damaged connectors.
NOTE: Loose connectors must be disconnected and examined for further wear or damage.
     (d) If a problem is found with the harnesses or connectors:
       1 Replace W04 HARNESS [4088KS] AMM 73-21-64-000-802 and AMM 73-21-64-400-802, or
       2 Replace WC08 HARNESS-CORE [4094KS] AMM 73-21-68-000-802 and AMM 73-21-68-400-802, or
       3 Replace W03 HARNESS [4087KS] AMM 73-21-63-000-802 and AMM 73-21-63-400-802.
       4 Do the test given in Para. 3.
   (5) If no problems are found with the harnesses or the fault continues, use a PLIERS - JAWED, SOFT to disconnect the electrical connectors P5 (4000KS-P5) and P6 (4000KS-P6) from the EEC (4000KS), interconnect J108 (4111VC)/P108 (4111VC-A) and connectors P25 (4052KS-P25) and P24 (4052KS-P24) from the HPC SVA primary (4052KS).
     (a) Examine the pins and sockets (contacts) for alignment and damage. Look for contacts pushed rearward into the connector face. Replace parts as necessary.
     (b) Clean the contacts with contact cleaner and clean cloth per SPOP 6. Blow dry with air (at less than 30 psi) across the connector face AMM 70-70-00-910-803.
     (c) Reconnect the electrical connectors P5 (4000KS-P5) and P6 (4000KS-P6) to the EEC (4000KS), interconnect J108 (4111VC)/P108 (4111VC-A) and connectors P25 (4052KS-P25) and P24 (4052KS-P24) to the HPC SVA primary (4052KS).
     (d) Do the test given in Para. 3.
   (6) If the fault continues:
     (a) Disconnect the electrical connectors P5 (4000KS-P5) and P6 (4000KS-P6) from the EEC (4000KS), interconnect J108 (4111VC)/P108 (4111VC-A) and connectors P25 (4052KS-P25) and P24 (4052KS-P24) from the HPC SVA primary (4052KS). Use a MULTIMETER - STANDARD to test the HPC SVA primary (4052KS) Linear Variable Differential Transformer (LVDT) and Torque Motor (TM) circuits in the harnesses. Refer to Table 1 and Table 2. Look for:
       1 Wire-to-wire shorts
       2 Shorts to ground
       3 Continuity (less than 5 ohms resistance).
NOTE: A short to ground is found when the resistance is less than 100 000 (100K) ohms.
Table 1: HPC SVA Primary LVDT Channel A Connector Contacts
W04 (4088KS) Harness P5 (4000KS-P5) EEC(4000KS) Connector Contacts
W04 (4088KS) Harness J108 (4111VC) Connector Contacts
WC08 (4094KS) Harness P108 (4111VC-A) Connector Contacts
WC08 (4094KS) Harness P25 (4052KS-P25) HPC SVA Primary (4052KS) Connector Contacts
JJ
20
20
8
x
21
21
9
e
6
6
12
C
7
7
3
D
19
19
11

Table 2: HPC SVA Primary LVDT Channel A Connector Contacts
W03 (4087KS) Harness P6 (4000KS-P6) EEC (4000KS) Connector Contacts
W03 (4087KS) Harness P24 (4052KS-P24) HPC SVA Primary (4052KS) Connector Contacts
t
5
GG
6

     (b) If a problem is found with the harnesses or connectors:
       1 Replace W04 HARNESS [4088KS] AMM 73-21-64-000-802 and AMM 73-21-64-400-802, or
       2 Replace WC08 HARNESS-CORE [4094KS] AMM 73-21-68-000-802 and AMM 73-21-68-000-802, or
       3 Replace W03 HARNESS [4087KS] AMM 73-21-63-000-802 and AMM 73-21-63-400-802.
       4 Do the test given in Para. 3.
   (7) If no problems are found with the harnesses or the fault continues:
     (a) Replace PRIMARY ACTUATOR-HPC STATOR VANE [4052KS] AMM 75-31-02-000-801 and AMM 75-31-02-400-801.
     (b) Do the test given in Para. 3.
   (8) If no problems are found with the harnesses or the fault continues:
     (a) Replace [4000KS] AMM 73-21-01-000-801 and AMM 73-21-01-400-801.
     (b) Do the test given in Para. 3.
5. Close-up
Subtask 75-31-00-860-062-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
     (a) Close the thrust reverser cowl-doors AMM 78-36-00-410-802.