Ignition/Exciter #1 and #2 Failure
TASK 74-00-00-810-833-A
Ignition/Exciter #1 and #2 Failure
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 74-00-00-710-138-A ** ON A/C NOT FOR ALL
Subtask 74-00-00-810-111-A ** ON A/C NOT FOR ALL
Subtask 74-00-00-860-078-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:37:00 UTC
Ignition/Exciter #1 and #2 Failure
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 74-00-00-810-831-A | Ignition/Exciter #1 Failure |
| TSM TASK 74-00-00-810-832-A | Ignition/Exciter #2 Failure |
Subtask 74-00-00-710-138-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault IsolationSubtask 74-00-00-810-111-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
(1) Do the troubleshooting procedure (Ref. TSM TASK 74-00-00-810-831).
(2) Do the troubleshooting procedure (Ref. TSM TASK 74-00-00-810-832).
5. Close-up(1) Do the troubleshooting procedure (Ref. TSM TASK 74-00-00-810-831).
(2) Do the troubleshooting procedure (Ref. TSM TASK 74-00-00-810-832).
Subtask 74-00-00-860-078-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(1) Make sure that the work area is clean and clear of tools and other items.