IDG FOC Delta Pressure Sensor Electrical Failure Channel A and B
TASK 71-00-00-810-893-A
IDG FOC Delta Pressure Sensor Electrical Failure Channel A and B
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 71-00-00-710-152-A ** ON A/C NOT FOR ALL
Subtask 71-00-00-810-160-A ** ON A/C NOT FOR ALL
Subtask 71-00-00-860-106-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:35:08 UTC
IDG FOC Delta Pressure Sensor Electrical Failure Channel A and B
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 71-00-00-810-836-A | IDG FOC Delta Pressure Sensor Electrical Failure Channel A |
| TSM TASK 71-00-00-810-837-A | IDG FOC Delta Pressure Sensor Electrical Failure Channel B |
Subtask 71-00-00-710-152-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault IsolationSubtask 71-00-00-810-160-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follow:
(1) Do the troubleshooting procedure (Ref. TSM TASK 71-00-00-810-836).
(2) Do the troubleshooting procedure (Ref. TSM TASK 71-00-00-810-837).
5. Close-up(1) Do the troubleshooting procedure (Ref. TSM TASK 71-00-00-810-836).
(2) Do the troubleshooting procedure (Ref. TSM TASK 71-00-00-810-837).
Subtask 71-00-00-860-106-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(1) Make sure that the work area is clean and clear of tools and other items.