W DOC AIRBUS | TSM A320F

IDG FOC Delta Pressure Sensor Electrical Failure Channel A and B


TASK 71-00-00-810-893-A
IDG FOC Delta Pressure Sensor Electrical Failure Channel A and B


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 71-00-00-810-836-A
IDG FOC Delta Pressure Sensor Electrical Failure Channel A
TSM TASK 71-00-00-810-837-A
IDG FOC Delta Pressure Sensor Electrical Failure Channel B
3. Fault Confirmation
Subtask 71-00-00-710-152-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 71-00-00-810-160-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follow:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 71-00-00-810-836).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 71-00-00-810-837).
5. Close-up
Subtask 71-00-00-860-106-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:35:08 UTC