APU AUTO SHUT DOWN - NO ACCELERATION, APU Flow Divider (8024KM) (APS 3200)
TASK 49-00-81-810-876-A
APU AUTO SHUT DOWN - NO ACCELERATION, APU Flow Divider (8024KM) (APS 3200)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-81-710-254-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 49-00-81-810-181-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:31 UTC
APU AUTO SHUT DOWN - NO ACCELERATION, APU Flow Divider (8024KM) (APS 3200)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 49-00-81-810-900-A | APU SLOW START, Start System (APS 3200) |
| AMM 49-00-00-710-008 | Operational Test of the APU |
| AMM 49-11-11-000-003 | Removal of the Power Plant (APU) (APS 3200) |
| AMM 49-11-11-400-003 | Installation of the Power Plant (APU) (APS 3200) |
| AMM 49-31-41-000-002 | Removal of the Pilot Fuel Nozzles and Manifold (APS 3200) |
| AMM 49-31-41-400-002 | Installation of the Pilot Fuel Nozzles and Manifold (APS 3200) |
| AMM 49-31-42-000-003 | Removal of the Main Fuel Nozzles and Manifold (APS 3200) |
| AMM 49-31-42-400-005 | Installation of the Main Fuel Nozzles and Manifold (APS 3200) |
| AMM 49-32-12-000-002 | Removal of the Flow Divider (APS 3200) |
| AMM 49-32-12-400-002 | Installation of the Flow Divider (APS 3200) |
| AMM 49-61-34-000-002 | Removal of the Electronic Control Box (ECB) (APS 3200) |
| AMM 49-61-34-400-002 | Installation of the Electronic Control Box (ECB) (APS 3200) |
| AMM 49-73-00-00- |
Subtask 49-00-81-710-254-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 49-00-81-810-181-A ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:
FLOW DIVIDER (8024KM):
Fault Code Number: 053
Interrogate CFDS for APU fault message. Use prompts (>) to go to the fault conditions screen AMM 49-73-00-00-.
Print Fault Condition Screen and review APU speed (NA).
(a) If speed (NA) is less than 30%:
Subtask 49-00-81-710-255-A ** ON A/C NOT FOR ALL FLOW DIVIDER (8024KM):
Fault Code Number: 053
NOTE: The APU SHUTDOWNS report gives the maintenance message:
NO ACCELERATION - FLOW DIVIDER (8024KM)
APU Auto Shut Down Fault Code Number: 053
NO ACCELERATION - FLOW DIVIDER (8024KM)
APU Auto Shut Down Fault Code Number: 053
- replace the
FLOW DIVIDER (8024KM) AMM 49-32-12-000-002 and AMM 49-32-12-400-002.
Interrogate CFDS for APU fault message. Use prompts (>) to go to the fault conditions screen AMM 49-73-00-00-.
Print Fault Condition Screen and review APU speed (NA).
(a) If speed (NA) is less than 30%:
- Do the TSM procedure (Ref. TSM TASK 49-00-81-810-900).
- replace the Pilot FUEL-NOZZLE AMM 49-31-41-000-002 and AMM 49-31-41-400-002.
- replace the Main FUEL-NOZZLE AMM 49-31-42-000-003 and AMM 49-31-42-400-005.
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-002 and AMM 49-61-34-400-002.
- replace the APU [4005KM] AMM 49-11-11-000-003 and AMM 49-11-11-400-003.
B. Do the test given in Para. 3.