APU AUTO SHUT DOWN - NO ACCELERATION (Deceleration), Fuel System Fault (APS 3200)


TASK 49-00-00-810-898-A
APU AUTO SHUT DOWN - NO ACCELERATION (Deceleration), Fuel System Fault (APS 3200)


1. Possible Causes
  • MAGNETIC DRAIN PLUG
  • FUEL FLOW DIVIDER (8024KM)
  • FUEL CONTROL UNIT (8022KM)
  • SECONDARY FUEL NOZZLES
  • wiring
  • ELECTRONIC CONTROL BOX [59KD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 49-00-81-810-900-A
APU SLOW START, Start System (APS 3200)
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-31-42-000-003
Removal of the Main Fuel Nozzles and Manifold (APS 3200)
AMM 49-31-42-400-005
Installation of the Main Fuel Nozzles and Manifold (APS 3200)
AMM 49-32-11-000-002
Removal of the Fuel Control Unit (APS 3200)
AMM 49-32-11-400-002
Installation of the Fuel Control Unit (APS 3200)
AMM 49-32-12-000-002
Removal of the Flow Divider (APS 3200)
AMM 49-32-12-400-002
Installation of the Flow Divider (APS 3200)
ASM 496102
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
AMM 49-73-00-00-
AMM 49-91-42-200-003
Inspection of the Magnetic Drain Plug (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-244-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-00-810-149-C ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:

FUEL CTL UNIT (8022KM) / FUEL FLOW DIVIDER (8024KM):
Fault Code Number: 052


NOTE: The APU SHUTDOWNS report gives the maintenance message:
NO ACCELERATION - FUEL CTL UNIT (8022KM) / FUEL FLOW DIVIDER (8024KM)
APU Auto Shut Down Fault Code Number: 052

  • do a check for blockage of the air inlet.
   (1) If the fault continues:
Interrogate CFDS for APU fault message. Use prompts (>) to go to the fault conditions screen AMM 49-73-00-00-.

Print Fault Condition Screen and review EGT.

     (a) If EGT is more than or equal to 650 deg.C:
     (b) If the EGT is less than 650 deg.C:
       1 If the fault continues:
       2 If the fault continues:
       3 If the fault continues:
       4 If the fault continues:
Subtask 49-00-00-710-245-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.