Loss of the Right-Wing Leak Detection


TASK 36-22-00-810-818-A
Loss of the Right-Wing Leak Detection


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 36-22-00-810-806-A
Loss of the Leak Detection Loop A on the Right Wing
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
3. Fault Confirmation
Subtask 36-22-00-710-069-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the BMC1 and BMC2 (with the CFDS) AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-22-00-810-067-B ** ON A/C NOT FOR ALL
A. If the test gives these two maintenance messages on the BMC1 : R WING LOOP A INOP and on the BMC2 : BMC2:
   (1) Do this trouble shooting procedure (Ref. TSM TASK 36-22-00-810-806).