Loss of the Leak Detection Loop A on the Right Wing
TASK 36-22-00-810-806-A
Loss of the Leak Detection Loop A on the Right Wing
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-22-00-710-050-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-055-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:02 UTC
Loss of the Leak Detection Loop A on the Right Wing
1. Possible Causes
- BMC-1 [1HA1]
- wiring
- sensing element
wiring from the connector AA/4D to the sensing element (80HF) wiring from the sensing element (39HF) to the sensing element (42HF) wiring from the sensing element (47HF) to the connector AA/5D
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-00-740-001 | BITE Test of the BMC 1(2) |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| AMM 36-22-00-100-801 | Clean the Overheat Detection System (OHDS) Connectors and Apply the Electrical Insulating Compound |
| ASM 362201 | |
| AMM 36-22-16-000-001 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-000-004 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-000-005 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-000-006 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-400-001 | Installation of the Overheat Sensing Elements |
| AMM 36-22-16-400-004 | Installation of the Overheat Sensing Elements |
| AMM 36-22-16-400-005 | Installation of the Overheat Sensing Elements |
| AMM 36-22-16-400-007 | Installation of the Overheat Sensing Elements |
Subtask 36-22-00-710-050-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-055-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
R WING LOOP A INOP
Subtask 36-22-00-710-051-A ** ON A/C NOT FOR ALL R WING LOOP A INOP
- remove the BMC-1 [1HA1] AMM 36-11-34-000-001.
- do a continuity check of the R wing loop A from pin AA/4D of the BMC1 to pin AA/5D of the BMC1 ASM 362201.
NOTE: This procedure is related to the loss of the wing-loop detection signal or to incorrect continuity of the loop.
The resistance of the loop must be less than 15 ohms at ambient temperature.
The BMC gives the maintenance message when the resistance of the loop is more than 75 ohms (discontinuity).
There is continuity when the resistance of the loop is less than 75 ohms.
(1) If there is continuity and the resistance of the loop is between 15 ohms and 75 ohms: The resistance of the loop must be less than 15 ohms at ambient temperature.
The BMC gives the maintenance message when the resistance of the loop is more than 75 ohms (discontinuity).
There is continuity when the resistance of the loop is less than 75 ohms.
- do a check and clean all the connections ASM 362201 to remove contamination and decrease the resistance of the loop AMM 36-22-00-100-801.
- replace the BMC-1 [1HA1] AMM 36-11-34-400-001.
- do a check of the wiring from pin AA/4D of the BMC1 to the cable (37HF) (found in the wing) and from pin AA/5D of the BMC1 to the cable (48HF) (found in the fuselage) ASM 362201.
- repair the wiring .
- install the BMC-1 [1HA1] AMM 36-11-34-400-001.
- do a visual inspection of the sensing elements on the R wing loop A.
- replace the sensing element .
- install the BMC-1 [1HA1] AMM 36-11-34-400-001.
- do a continuity check of each sensing element, one after the other.
- replace the sensing element: AMM 36-22-16-000-001 AMM 36-22-16-000-004 AMM 36-22-16-000-005 AMM 36-22-16-000-006 AMM 36-22-16-400-001 AMM 36-22-16-400-004 AMM 36-22-16-400-005 AMM 36-22-16-400-007.
- install the BMC-1 [1HA1] AMM 36-11-34-400-001.
- do a check and repair the
wiring from the connector AA/4D to the sensing element (80HF) ASM 362201. - do a check and repair the
wiring from the sensing element (39HF) to the sensing element (42HF) ASM 362201. - do a check and repair the
wiring from the sensing element (47HF) to the connector AA/5D ASM 362201. - install the BMC-1 [1HA1] AMM 36-11-34-400-001.
B. Do the test given in Para. 3.