W DOC AIRBUS | TSM A320F

Failure of the Pressure Transducer of the R Static Pressure ADM or of the L Static Pressure ADM


TASK 34-11-00-810-901-A
Failure of the Pressure Transducer of the R Static Pressure ADM or of the L Static Pressure ADM


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 34-11-00-810-816-A
Failure of the Pressure Transducer of the L Static Pressure ADM
TSM TASK 34-11-00-810-817-A
Failure of the Pressure Transducer of the R Static Pressure ADM
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
3. Fault Confirmation
Subtask 34-11-00-740-143-A ** ON A/C NOT FOR ALL
A. Test
Do the interface test of the ADR (system 2) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-11-00-810-230-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADM6 (19FP6):
Subtask 34-11-00-810-231-A ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message ADM7 (19FP7):