W DOC AIRBUS | TSM A320F

Failure of the Pressure Transducer of the R Static Pressure ADM


TASK 34-11-00-810-817-A
Failure of the Pressure Transducer of the R Static Pressure ADM


1. Possible Causes
  • ADM-R STATIC PRESSURE [19FP6]
  • ADIRU-2 [1FP2]
  • wiring between R static pressure ADM (19FP6) and the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AWM 341110
AMM 34-11-17-000-001
Removal of the Air Data Module
AMM 34-11-17-400-001
Installation of the Air Data Module
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
3. Fault Confirmation
Subtask 34-11-00-740-082-A
A. Test
Do the Interface test of the ADR (system 2) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-11-00-810-066-A
A. If the test gives the maintenance message ADM 19FP6 or ADM (19FP6):
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring between R static pressure ADM (19FP6) and the first terminal block pins A, C, E/A AWM 341110.
Subtask 34-11-00-740-083-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:14 UTC