Loss of the Air Data Display on the CAPT PFD with the AIR DATA Selector Switch at CAPT/3
TASK 34-11-00-810-895-A
Loss of the Air Data Display on the CAPT PFD with the AIR DATA Selector Switch at CAPT/3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-700-056-A
Subtask 34-11-00-810-214-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:19 UTC
Loss of the Air Data Display on the CAPT PFD with the AIR DATA Selector Switch at CAPT/3
1. Possible Causes
- SEL SW-AIR DATA [15FP]
wiring of the AIR DATA selector switch (15FP)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 34-11-00-810-868-A | Loss of the Attitude Data on the CAPT PFD with the ATT HDG Selector Switch at CAPT/3 |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
| ASM 316804 |
Subtask 34-11-00-700-056-A
A. Test
Not applicable, the fault is evident.
4. Fault IsolationNot applicable, the fault is evident.
Subtask 34-11-00-810-214-A
A. If the air data indications go out of view on the CAPT PFD with the AIR DATA selector switch at CAPT/3:
- remove the DMC1 and DMC3 AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check for a ground signal at the pin AB/4E of the DMC1 and DMC3.
- replace the SEL SW-AIR DATA [15FP] .
- do a check and repair the
wiring of the AIR DATA selector switch (15FP) :
pin A/5 to the ground point
pin A/6 to the first terminal block ASM 316804.
- do the procedure (Ref. TSM TASK 34-11-00-810-868).