W DOC AIRBUS | TSM A320F

Loss of the Attitude Data on the CAPT PFD with the ATT HDG Selector Switch at CAPT/3


TASK 34-11-00-810-868-A
Loss of the Attitude Data on the CAPT PFD with the ATT HDG Selector Switch at CAPT/3


1. Possible Causes
  • SEL SW-ATT HDG [13FP]
  • wiring of the ATT HDG selector switch (13FP)
  • RELAY-ADIRS 3 28VDC CONTROL [16FP]
  • DIODE (18FP)
  • wiring of the ADIRS3 28VDC control relay (16FP)
  • C/B-NAV PROBES/ADIRU3/PWR/SWTG [8FP]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 34-14-00-810-898-A
Loss of the AC Supply of the ADIRU3
TSM TASK 34-14-00-810-901-A
Loss of the DC Supply of the ADIRU3
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
ASM 316804
ASM 341101
AMM 34-14-00-740-001
Interface Test of the IR
3. Fault Confirmation
Subtask 34-11-00-710-086-A
A. Test
   (1) Not applicable, the fault is evident.
4. Fault Isolation
Subtask 34-11-00-810-189-B
A. If the attitude data go out of view on the CAPT PFD with the ATT HDG selector switch at CAPT/3:
   (1) If there is no ground signal:
  • replace the SEL SW-ATT HDG [13FP] .
     (a) If the fault continues:
  • do a check and repair the wiring of the ATT HDG selector switch (13FP):
    pin A/5 to the ground point
    pin A/6 to the first terminal block ASM 316804.
   (2) If there is a ground signal:
     (a) If the test gives the maintenance message ADIRU3 (1FP3) AC SUPPLY:
     (b) If the test gives the maintenance message ADIRU3 (1FP3) DC SUPPLY:
     (c) If the test does not give the maintenance messages ADIRU3 (1FP3) AC SUPPLY or ADIRU3 (1FP3) DC SUPPLY:
  • replace the RELAY-ADIRS 3 28VDC CONTROL [16FP] .
       1 If the fault continues:
  • replace the DIODE (18FP).
         a If the fault continues:
do a check of the wiring of the ADIRS3 28VDC control relay (16FP):
. pin A/4 to the circuit breaker (8FP)
. pin A/X to diode (18FP) pin 2
. pin A/Z to the ground point
. pin A/B to ADIRS3 power shedding relay (14FP) pin A/C1
ASM 341101.
  • If there is no continuity:
    repair the above wirings.
  • If there is continuity:
    do a check of the wiring of the ATT HDG selector switch (13FP):
    pin A/1 to diode (18FP) pin 1
    pin A/2 to the first terminal block
    ASM 341101.
    . If there is no continuity:
    * repair the above wiring.
    . If there is continuity:
    * replace the C/B-NAV PROBES/ADIRU3/PWR/SWTG [8FP] .
[Rev.8 from Aug 2018] 2026.04.04 04:32:17 UTC