Loss of the DC Supply of the ADIRU3
TASK 34-14-00-810-901-A
Loss of the DC Supply of the ADIRU3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-14-00-740-213-A 4. Fault Isolation
Subtask 34-14-00-810-155-A
[Rev.8 from Aug 2018]
2026.04.04 04:40:24 UTC
Loss of the DC Supply of the ADIRU3
1. Possible Causes
- ADIRU-3 [1FP3]
wiring between ADIRU3 pin AC/8 and the first terminal block - RELAY-ADIRS 3 PWR SHEDDING [14FP]
wiring of the ADIRS 3 PWR SHEDDING relay (14FP) wiring from the relay (14FP) pins A2, X1 to the circuit breaker (6FP3) - C/B-ADIRS/ADIRU/3/28VDC [6FP3]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 341101 | |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-14-00-740-004 | SYSTEM TEST of the Inertial Reference (IR) |
Subtask 34-14-00-740-213-A 4. Fault Isolation
Subtask 34-14-00-810-155-A
A. If the test gives the maintenance message ADIRU3 (1FP3) DC SUPPLY:
Subtask 34-14-00-740-214-A - remove the ADIRU-3 [1FP3] AMM 34-12-34-000-001
- do a check for a ground signal at pin AC/8 of the rack connector.
- repair the
wiring between ADIRU3 pin AC/8 and the first terminal block ASM 341101 - install the ADIRU3 AMM 34-12-34-400-001.
- do a check for 28VDC at pin AC/7 of the rack connector.
- install a new ADIRU3.
- replace the RELAY-ADIRS 3 PWR SHEDDING [14FP] .
- install the ADIRU3.
- do a check and repair the
wiring of the ADIRS 3 PWR SHEDDING relay (14FP)
. pin X2 to the ground point
. pin A1 to the ADIRU 3 (1FP3) pin AC/7
ASM 341101.
- install the ADIRU 3.
- do a check of the
wiring from the relay (14FP) pins A2, X1 to the circuit breaker (6FP3)
ASM 341101.
. If there is no continuity:
- repair the above wiring
- install the ADIRU 3.
. If there is continuity:
- replace the C/B-ADIRS/ADIRU/3/28VDC [6FP3]
- install the ADIRU 3.
B. Do the test given in Para. 3.